Radiation calculations for the main shielding wall for LHCb,2nd Part

Radiation fields behind the main shielding wall separating the LHCb detector from its counting rooms have been calculated for different conceptual designs using the Monte Carlo code FLUKA. Implication of different wall thicknesses as well as of appropriately shielded access openings and cable ducts...

Descripción completa

Detalles Bibliográficos
Autores principales: Lacarrère, D, Lindner, R
Lenguaje:eng
Publicado: 1998
Materias:
Acceso en línea:http://cds.cern.ch/record/684493
_version_ 1780901458104811520
author Lacarrère, D
Lindner, R
author_facet Lacarrère, D
Lindner, R
author_sort Lacarrère, D
collection CERN
description Radiation fields behind the main shielding wall separating the LHCb detector from its counting rooms have been calculated for different conceptual designs using the Monte Carlo code FLUKA. Implication of different wall thicknesses as well as of appropriately shielded access openings and cable ducts on the radiation level behind the shielding wall are examined. It is shown that leakage of stray radiation through the vertical shafts to the surface of the earth gives rise to doses that are less than dose equivalent limit for Supervised Radiation Area.1
id cern-684493
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1998
record_format invenio
spelling cern-6844932019-09-30T06:29:59Zhttp://cds.cern.ch/record/684493engLacarrère, DLindner, RRadiation calculations for the main shielding wall for LHCb,2nd PartDetectors and Experimental TechniquesRadiation fields behind the main shielding wall separating the LHCb detector from its counting rooms have been calculated for different conceptual designs using the Monte Carlo code FLUKA. Implication of different wall thicknesses as well as of appropriately shielded access openings and cable ducts on the radiation level behind the shielding wall are examined. It is shown that leakage of stray radiation through the vertical shafts to the surface of the earth gives rise to doses that are less than dose equivalent limit for Supervised Radiation Area.1LHCb-98-023oai:cds.cern.ch:6844931998-02-18
spellingShingle Detectors and Experimental Techniques
Lacarrère, D
Lindner, R
Radiation calculations for the main shielding wall for LHCb,2nd Part
title Radiation calculations for the main shielding wall for LHCb,2nd Part
title_full Radiation calculations for the main shielding wall for LHCb,2nd Part
title_fullStr Radiation calculations for the main shielding wall for LHCb,2nd Part
title_full_unstemmed Radiation calculations for the main shielding wall for LHCb,2nd Part
title_short Radiation calculations for the main shielding wall for LHCb,2nd Part
title_sort radiation calculations for the main shielding wall for lhcb,2nd part
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/684493
work_keys_str_mv AT lacarrered radiationcalculationsforthemainshieldingwallforlhcb2ndpart
AT lindnerr radiationcalculationsforthemainshieldingwallforlhcb2ndpart