Cargando…

Monitoring, alignment and control of the RICH detectors

The physical quantities of the RICH detectors need to be monitored throughout the duration of the experiment to ensure that their performance remains within the design specifications. The present note describes all the physical quantities that need to be monitored and a description of possible devic...

Descripción completa

Detalles Bibliográficos
Autores principales: D'Ambrosio, C, Franek, B, Gaspar, C, Laub, M, Lindner, R, Muheim, F, Papanestis, A, Soler, FJP
Lenguaje:eng
Publicado: 2001
Materias:
Acceso en línea:http://cds.cern.ch/record/684661
_version_ 1780901461639561216
author D'Ambrosio, C
Franek, B
Gaspar, C
Laub, M
Lindner, R
Muheim, F
Papanestis, A
Soler, FJP
author_facet D'Ambrosio, C
Franek, B
Gaspar, C
Laub, M
Lindner, R
Muheim, F
Papanestis, A
Soler, FJP
author_sort D'Ambrosio, C
collection CERN
description The physical quantities of the RICH detectors need to be monitored throughout the duration of the experiment to ensure that their performance remains within the design specifications. The present note describes all the physical quantities that need to be monitored and a description of possible devices that could be implemented to achieve the specified level of control. In addition, the angular resolution of the RICH detectors depends on an accurate alignment of the system. Proposals for this alignment procedure are described.
id cern-684661
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2001
record_format invenio
spelling cern-6846612019-09-30T06:29:59Zhttp://cds.cern.ch/record/684661engD'Ambrosio, CFranek, BGaspar, CLaub, MLindner, RMuheim, FPapanestis, ASoler, FJPMonitoring, alignment and control of the RICH detectorsDetectors and Experimental TechniquesThe physical quantities of the RICH detectors need to be monitored throughout the duration of the experiment to ensure that their performance remains within the design specifications. The present note describes all the physical quantities that need to be monitored and a description of possible devices that could be implemented to achieve the specified level of control. In addition, the angular resolution of the RICH detectors depends on an accurate alignment of the system. Proposals for this alignment procedure are described.LHCb-2000-080oai:cds.cern.ch:6846612001-04-18
spellingShingle Detectors and Experimental Techniques
D'Ambrosio, C
Franek, B
Gaspar, C
Laub, M
Lindner, R
Muheim, F
Papanestis, A
Soler, FJP
Monitoring, alignment and control of the RICH detectors
title Monitoring, alignment and control of the RICH detectors
title_full Monitoring, alignment and control of the RICH detectors
title_fullStr Monitoring, alignment and control of the RICH detectors
title_full_unstemmed Monitoring, alignment and control of the RICH detectors
title_short Monitoring, alignment and control of the RICH detectors
title_sort monitoring, alignment and control of the rich detectors
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/684661
work_keys_str_mv AT dambrosioc monitoringalignmentandcontroloftherichdetectors
AT franekb monitoringalignmentandcontroloftherichdetectors
AT gasparc monitoringalignmentandcontroloftherichdetectors
AT laubm monitoringalignmentandcontroloftherichdetectors
AT lindnerr monitoringalignmentandcontroloftherichdetectors
AT muheimf monitoringalignmentandcontroloftherichdetectors
AT papanestisa monitoringalignmentandcontroloftherichdetectors
AT solerfjp monitoringalignmentandcontroloftherichdetectors