Performance of micro wire detector at a PSI test-beam

99-021 This note describes the behaviour of a Micro Wire Detector in a test-beam at the Paul Scherrer Institute (PSI), Switzerland. The results of the irradiation tests done with pion minus and proton/pion plus beams at intensities 2 10^4[1/mm^2 s] show no evidence of degradation of detector perform...

Descripción completa

Detalles Bibliográficos
Autores principales: Adeva, B, Gómez, F, Labbé, J C, Pfau, R, Pló, M, Rodríguez-Gónzalez, J
Lenguaje:eng
Publicado: 1999
Materias:
Acceso en línea:http://cds.cern.ch/record/684672
Descripción
Sumario:99-021 This note describes the behaviour of a Micro Wire Detector in a test-beam at the Paul Scherrer Institute (PSI), Switzerland. The results of the irradiation tests done with pion minus and proton/pion plus beams at intensities 2 10^4[1/mm^2 s] show no evidence of degradation of detector performance with respect to its laboratory operation parameters, previously determined with X-rays, up to an integrated charge of 150mC over the area of 12.8cm^2. The time resolution of the detector was also determined to be better than 21ns.