Performance of micro wire detector at a PSI test-beam

99-021 This note describes the behaviour of a Micro Wire Detector in a test-beam at the Paul Scherrer Institute (PSI), Switzerland. The results of the irradiation tests done with pion minus and proton/pion plus beams at intensities 2 10^4[1/mm^2 s] show no evidence of degradation of detector perform...

Descripción completa

Detalles Bibliográficos
Autores principales: Adeva, B, Gómez, F, Labbé, J C, Pfau, R, Pló, M, Rodríguez-Gónzalez, J
Lenguaje:eng
Publicado: 1999
Materias:
Acceso en línea:http://cds.cern.ch/record/684672
_version_ 1780901464054431744
author Adeva, B
Gómez, F
Labbé, J C
Pfau, R
Pló, M
Rodríguez-Gónzalez, J
author_facet Adeva, B
Gómez, F
Labbé, J C
Pfau, R
Pló, M
Rodríguez-Gónzalez, J
author_sort Adeva, B
collection CERN
description 99-021 This note describes the behaviour of a Micro Wire Detector in a test-beam at the Paul Scherrer Institute (PSI), Switzerland. The results of the irradiation tests done with pion minus and proton/pion plus beams at intensities 2 10^4[1/mm^2 s] show no evidence of degradation of detector performance with respect to its laboratory operation parameters, previously determined with X-rays, up to an integrated charge of 150mC over the area of 12.8cm^2. The time resolution of the detector was also determined to be better than 21ns.
id cern-684672
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1999
record_format invenio
spelling cern-6846722019-09-30T06:29:59Zhttp://cds.cern.ch/record/684672engAdeva, BGómez, FLabbé, J CPfau, RPló, MRodríguez-Gónzalez, JPerformance of micro wire detector at a PSI test-beamDetectors and Experimental Techniques99-021 This note describes the behaviour of a Micro Wire Detector in a test-beam at the Paul Scherrer Institute (PSI), Switzerland. The results of the irradiation tests done with pion minus and proton/pion plus beams at intensities 2 10^4[1/mm^2 s] show no evidence of degradation of detector performance with respect to its laboratory operation parameters, previously determined with X-rays, up to an integrated charge of 150mC over the area of 12.8cm^2. The time resolution of the detector was also determined to be better than 21ns.LHCb-99-021oai:cds.cern.ch:6846721999-06-17
spellingShingle Detectors and Experimental Techniques
Adeva, B
Gómez, F
Labbé, J C
Pfau, R
Pló, M
Rodríguez-Gónzalez, J
Performance of micro wire detector at a PSI test-beam
title Performance of micro wire detector at a PSI test-beam
title_full Performance of micro wire detector at a PSI test-beam
title_fullStr Performance of micro wire detector at a PSI test-beam
title_full_unstemmed Performance of micro wire detector at a PSI test-beam
title_short Performance of micro wire detector at a PSI test-beam
title_sort performance of micro wire detector at a psi test-beam
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/684672
work_keys_str_mv AT adevab performanceofmicrowiredetectoratapsitestbeam
AT gomezf performanceofmicrowiredetectoratapsitestbeam
AT labbejc performanceofmicrowiredetectoratapsitestbeam
AT pfaur performanceofmicrowiredetectoratapsitestbeam
AT plom performanceofmicrowiredetectoratapsitestbeam
AT rodriguezgonzalezj performanceofmicrowiredetectoratapsitestbeam