A long analog transmission line for the VELO read-out

The radiation level in the LHCb cavern strongly suggests to place the L1 Electronics behind the concrete wall to avoid Single Event Upset (SEU) in FPGA. For the VELO this implies the necessity for ~60 m long transmission lines from the VELO vacuum vessel to the L1 electronics. This note reports a fe...

Descripción completa

Detalles Bibliográficos
Autores principales: Frei, R, Gagliardi, G
Lenguaje:eng
Publicado: 2001
Materias:
Acceso en línea:http://cds.cern.ch/record/684680
Descripción
Sumario:The radiation level in the LHCb cavern strongly suggests to place the L1 Electronics behind the concrete wall to avoid Single Event Upset (SEU) in FPGA. For the VELO this implies the necessity for ~60 m long transmission lines from the VELO vacuum vessel to the L1 electronics. This note reports a feasibility study for such a long connection using twisted pair cables.