Cargando…

PSI run report of the micromegas detector-March 28-April 13 1999

99-020 A Micromegas prototype has been tested at PSI in a high flux pion beam. The main goal was the study of the rate of discharges in this environment, but we also report results on time resolution and pulse height distribution measurements. Discharge probabilities per particles of 4x10<SUP>...

Descripción completa

Detalles Bibliográficos
Autores principales: Perroud, Jean-Pierre, Ronga, F
Lenguaje:eng
Publicado: 1999
Materias:
Acceso en línea:http://cds.cern.ch/record/684720
_version_ 1780901474225618944
author Perroud, Jean-Pierre
Ronga, F
author_facet Perroud, Jean-Pierre
Ronga, F
author_sort Perroud, Jean-Pierre
collection CERN
description 99-020 A Micromegas prototype has been tested at PSI in a high flux pion beam. The main goal was the study of the rate of discharges in this environment, but we also report results on time resolution and pulse height distribution measurements. Discharge probabilities per particles of 4x10<SUP>-5</SUP> for a pure pi<SUP>-</SUP> beam of 215 MeV/c momentum and 10<SUP>-4</SUP> for a mixed pi<SUP>+</SUP> and protons beam of 350 MeV/c momentum have been measured. It turned out to be constant up to high rates of 48 MHz in the chamber. These results on the discharges may have been worsened by the gas mixture used for this run, namely argon and CO<SUB>2</SUB>. Micromegas doesn't seem to be LHC compliant in it's actual form, in spite of its many qualities, which merit more investigation.
id cern-684720
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1999
record_format invenio
spelling cern-6847202019-09-30T06:29:59Zhttp://cds.cern.ch/record/684720engPerroud, Jean-PierreRonga, FPSI run report of the micromegas detector-March 28-April 13 1999Detectors and Experimental Techniques99-020 A Micromegas prototype has been tested at PSI in a high flux pion beam. The main goal was the study of the rate of discharges in this environment, but we also report results on time resolution and pulse height distribution measurements. Discharge probabilities per particles of 4x10<SUP>-5</SUP> for a pure pi<SUP>-</SUP> beam of 215 MeV/c momentum and 10<SUP>-4</SUP> for a mixed pi<SUP>+</SUP> and protons beam of 350 MeV/c momentum have been measured. It turned out to be constant up to high rates of 48 MHz in the chamber. These results on the discharges may have been worsened by the gas mixture used for this run, namely argon and CO<SUB>2</SUB>. Micromegas doesn't seem to be LHC compliant in it's actual form, in spite of its many qualities, which merit more investigation.LHCb-99-020oai:cds.cern.ch:6847201999-06-14
spellingShingle Detectors and Experimental Techniques
Perroud, Jean-Pierre
Ronga, F
PSI run report of the micromegas detector-March 28-April 13 1999
title PSI run report of the micromegas detector-March 28-April 13 1999
title_full PSI run report of the micromegas detector-March 28-April 13 1999
title_fullStr PSI run report of the micromegas detector-March 28-April 13 1999
title_full_unstemmed PSI run report of the micromegas detector-March 28-April 13 1999
title_short PSI run report of the micromegas detector-March 28-April 13 1999
title_sort psi run report of the micromegas detector-march 28-april 13 1999
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/684720
work_keys_str_mv AT perroudjeanpierre psirunreportofthemicromegasdetectormarch28april131999
AT rongaf psirunreportofthemicromegasdetectormarch28april131999