Cargando…

Gas Gain Stabilisation System prototype for the TRT

The TRT closed-loop gas system needs a special control and monitoring functionality which should maintain a stability of gas gain in spite of unavoidable changes in gas composition and variation of environmental conditions (temperature, pressure etc.). We describe a prototype set-up for the Gas Gain...

Descripción completa

Detalles Bibliográficos
Autores principales: Deptuch, M, Hajduk, Z, Jelen, K, Kisielewska, D, Koperny, S, Kowalski, T, Mindur, B, Olszowska, J
Lenguaje:eng
Publicado: 2002
Materias:
Acceso en línea:http://cds.cern.ch/record/685334
_version_ 1780901487711354880
author Deptuch, M
Hajduk, Z
Jelen, K
Kisielewska, D
Koperny, S
Kowalski, T
Mindur, B
Olszowska, J
author_facet Deptuch, M
Hajduk, Z
Jelen, K
Kisielewska, D
Koperny, S
Kowalski, T
Mindur, B
Olszowska, J
author_sort Deptuch, M
collection CERN
description The TRT closed-loop gas system needs a special control and monitoring functionality which should maintain a stability of gas gain in spite of unavoidable changes in gas composition and variation of environmental conditions (temperature, pressure etc.). We describe a prototype set-up for the Gas Gain Stabilisation System build and tested at CERN on which basic ideas for algorithms and functionalities were tested. The system is based on special counter - reference straw, where X-ray 55Fe spectrum is measured. Preliminary results of the prototype reaction to rapid changes in working gas pressure and temperature are presented.
id cern-685334
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2002
record_format invenio
spelling cern-6853342019-09-30T06:29:59Zhttp://cds.cern.ch/record/685334engDeptuch, MHajduk, ZJelen, KKisielewska, DKoperny, SKowalski, TMindur, BOlszowska, JGas Gain Stabilisation System prototype for the TRTDetectors and Experimental TechniquesThe TRT closed-loop gas system needs a special control and monitoring functionality which should maintain a stability of gas gain in spite of unavoidable changes in gas composition and variation of environmental conditions (temperature, pressure etc.). We describe a prototype set-up for the Gas Gain Stabilisation System build and tested at CERN on which basic ideas for algorithms and functionalities were tested. The system is based on special counter - reference straw, where X-ray 55Fe spectrum is measured. Preliminary results of the prototype reaction to rapid changes in working gas pressure and temperature are presented.ATL-INDET-2002-010oai:cds.cern.ch:6853342002-02-06
spellingShingle Detectors and Experimental Techniques
Deptuch, M
Hajduk, Z
Jelen, K
Kisielewska, D
Koperny, S
Kowalski, T
Mindur, B
Olszowska, J
Gas Gain Stabilisation System prototype for the TRT
title Gas Gain Stabilisation System prototype for the TRT
title_full Gas Gain Stabilisation System prototype for the TRT
title_fullStr Gas Gain Stabilisation System prototype for the TRT
title_full_unstemmed Gas Gain Stabilisation System prototype for the TRT
title_short Gas Gain Stabilisation System prototype for the TRT
title_sort gas gain stabilisation system prototype for the trt
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/685334
work_keys_str_mv AT deptuchm gasgainstabilisationsystemprototypeforthetrt
AT hajdukz gasgainstabilisationsystemprototypeforthetrt
AT jelenk gasgainstabilisationsystemprototypeforthetrt
AT kisielewskad gasgainstabilisationsystemprototypeforthetrt
AT kopernys gasgainstabilisationsystemprototypeforthetrt
AT kowalskit gasgainstabilisationsystemprototypeforthetrt
AT mindurb gasgainstabilisationsystemprototypeforthetrt
AT olszowskaj gasgainstabilisationsystemprototypeforthetrt