Choice of the WLS fibres for the Tilecal calorimeter

We report on the criteria and measurements performed for the choice of the type of fibre that would equip the Tilecal Calorimeter. There were three types of candidate WLS fibres each from a different producer: BCF91A from Bicron, S250-100 from Pol.Hi.Tech and Y11(200)MSJ from Kuraray. The three prod...

Descripción completa

Detalles Bibliográficos
Autores principales: David, M, Gomes, A, Maio, A, Pina, J, Varanda, M J
Lenguaje:eng
Publicado: 2002
Materias:
Acceso en línea:http://cds.cern.ch/record/685358
_version_ 1780901492407926784
author David, M
Gomes, A
Maio, A
Pina, J
Varanda, M J
author_facet David, M
Gomes, A
Maio, A
Pina, J
Varanda, M J
author_sort David, M
collection CERN
description We report on the criteria and measurements performed for the choice of the type of fibre that would equip the Tilecal Calorimeter. There were three types of candidate WLS fibres each from a different producer: BCF91A from Bicron, S250-100 from Pol.Hi.Tech and Y11(200)MSJ from Kuraray. The three producers have a history of cooperation with the Tilecal/ATLAS group and some of those fibres were used to instrument several prototype modules of the Tilecal. After many tests, the fibres that were chosen to equip the Tilecal were the Y11(200)MSJ from Kuraray.
id cern-685358
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2002
record_format invenio
spelling cern-6853582019-09-30T06:29:59Zhttp://cds.cern.ch/record/685358engDavid, MGomes, AMaio, APina, JVaranda, M JChoice of the WLS fibres for the Tilecal calorimeterDetectors and Experimental TechniquesWe report on the criteria and measurements performed for the choice of the type of fibre that would equip the Tilecal Calorimeter. There were three types of candidate WLS fibres each from a different producer: BCF91A from Bicron, S250-100 from Pol.Hi.Tech and Y11(200)MSJ from Kuraray. The three producers have a history of cooperation with the Tilecal/ATLAS group and some of those fibres were used to instrument several prototype modules of the Tilecal. After many tests, the fibres that were chosen to equip the Tilecal were the Y11(200)MSJ from Kuraray.ATL-TILECAL-2003-001oai:cds.cern.ch:6853582002-04-29
spellingShingle Detectors and Experimental Techniques
David, M
Gomes, A
Maio, A
Pina, J
Varanda, M J
Choice of the WLS fibres for the Tilecal calorimeter
title Choice of the WLS fibres for the Tilecal calorimeter
title_full Choice of the WLS fibres for the Tilecal calorimeter
title_fullStr Choice of the WLS fibres for the Tilecal calorimeter
title_full_unstemmed Choice of the WLS fibres for the Tilecal calorimeter
title_short Choice of the WLS fibres for the Tilecal calorimeter
title_sort choice of the wls fibres for the tilecal calorimeter
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/685358
work_keys_str_mv AT davidm choiceofthewlsfibresforthetilecalcalorimeter
AT gomesa choiceofthewlsfibresforthetilecalcalorimeter
AT maioa choiceofthewlsfibresforthetilecalcalorimeter
AT pinaj choiceofthewlsfibresforthetilecalcalorimeter
AT varandamj choiceofthewlsfibresforthetilecalcalorimeter