Cargando…
Choice of the WLS fibres for the Tilecal calorimeter
We report on the criteria and measurements performed for the choice of the type of fibre that would equip the Tilecal Calorimeter. There were three types of candidate WLS fibres each from a different producer: BCF91A from Bicron, S250-100 from Pol.Hi.Tech and Y11(200)MSJ from Kuraray. The three prod...
Autores principales: | , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2002
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/685358 |
_version_ | 1780901492407926784 |
---|---|
author | David, M Gomes, A Maio, A Pina, J Varanda, M J |
author_facet | David, M Gomes, A Maio, A Pina, J Varanda, M J |
author_sort | David, M |
collection | CERN |
description | We report on the criteria and measurements performed for the choice of the type of fibre that would equip the Tilecal Calorimeter. There were three types of candidate WLS fibres each from a different producer: BCF91A from Bicron, S250-100 from Pol.Hi.Tech and Y11(200)MSJ from Kuraray. The three producers have a history of cooperation with the Tilecal/ATLAS group and some of those fibres were used to instrument several prototype modules of the Tilecal. After many tests, the fibres that were chosen to equip the Tilecal were the Y11(200)MSJ from Kuraray. |
id | cern-685358 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2002 |
record_format | invenio |
spelling | cern-6853582019-09-30T06:29:59Zhttp://cds.cern.ch/record/685358engDavid, MGomes, AMaio, APina, JVaranda, M JChoice of the WLS fibres for the Tilecal calorimeterDetectors and Experimental TechniquesWe report on the criteria and measurements performed for the choice of the type of fibre that would equip the Tilecal Calorimeter. There were three types of candidate WLS fibres each from a different producer: BCF91A from Bicron, S250-100 from Pol.Hi.Tech and Y11(200)MSJ from Kuraray. The three producers have a history of cooperation with the Tilecal/ATLAS group and some of those fibres were used to instrument several prototype modules of the Tilecal. After many tests, the fibres that were chosen to equip the Tilecal were the Y11(200)MSJ from Kuraray.ATL-TILECAL-2003-001oai:cds.cern.ch:6853582002-04-29 |
spellingShingle | Detectors and Experimental Techniques David, M Gomes, A Maio, A Pina, J Varanda, M J Choice of the WLS fibres for the Tilecal calorimeter |
title | Choice of the WLS fibres for the Tilecal calorimeter |
title_full | Choice of the WLS fibres for the Tilecal calorimeter |
title_fullStr | Choice of the WLS fibres for the Tilecal calorimeter |
title_full_unstemmed | Choice of the WLS fibres for the Tilecal calorimeter |
title_short | Choice of the WLS fibres for the Tilecal calorimeter |
title_sort | choice of the wls fibres for the tilecal calorimeter |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/685358 |
work_keys_str_mv | AT davidm choiceofthewlsfibresforthetilecalcalorimeter AT gomesa choiceofthewlsfibresforthetilecalcalorimeter AT maioa choiceofthewlsfibresforthetilecalcalorimeter AT pinaj choiceofthewlsfibresforthetilecalcalorimeter AT varandamj choiceofthewlsfibresforthetilecalcalorimeter |