Electrical test results from ATLAS-SCT end-cap modules
The LHC operating conditions present several challenges to the module performance of the ATLAS Semiconductor Tracker (SCT). This detector consists of four cylindrical barrel layers of silicon strip detectors and of 18 disks in the forward and backward direction. Four different module designs exist,...
Autores principales: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2003
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/685496 |
_version_ | 1780901520090333184 |
---|---|
author | Mangin-Brinet, M Clark, A G Donega, M D'Onofrio, M Ferrère, D Mikulec, B Moed, S Weber, M Hartjes, F Muijs, S Peeters, S Chouridou, S Roe, S Wallny, R Bernabeu, J Lacasta, C Feld, L Ketterer, C Meinhardt, J Dolezal, Z Kodys, P Kubik, P Reznicek, P Allport, P P Dervan, P J Greenall, A Jackson, J N Jones, T J Phillips, P W Smith, N A Sutcliffe, P Tavera, M |
author_facet | Mangin-Brinet, M Clark, A G Donega, M D'Onofrio, M Ferrère, D Mikulec, B Moed, S Weber, M Hartjes, F Muijs, S Peeters, S Chouridou, S Roe, S Wallny, R Bernabeu, J Lacasta, C Feld, L Ketterer, C Meinhardt, J Dolezal, Z Kodys, P Kubik, P Reznicek, P Allport, P P Dervan, P J Greenall, A Jackson, J N Jones, T J Phillips, P W Smith, N A Sutcliffe, P Tavera, M |
author_sort | Mangin-Brinet, M |
collection | CERN |
description | The LHC operating conditions present several challenges to the module performance of the ATLAS Semiconductor Tracker (SCT). This detector consists of four cylindrical barrel layers of silicon strip detectors and of 18 disks in the forward and backward direction. Four different module designs exist, one for the barrel and three (inner, middle and outer) for the rings of the disks. A series of several end-cap module pre-production prototypes of inner, middle and outer types have been built and extensively characterized on single module test benches in the institutes of the collaboration. The scope of this document is to summarize the electrical performance measurements made in laboratory on these end-cap module pre-production prototypes, with special emphasis on the result of electrical tests after irradiation. As summarized in the conclusion, the electrical performance specifications are met before irradiation, but are exceeded after an irradiation dose of $1.5.10^{14}$p/cm$^2$, that is a fluence corresponding to half the total dose ATLAS-SCT is foreseen to receive during its life time. Higher threshold operation will then be required with a corresponding expected loss in tracking efficiency. |
id | cern-685496 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2003 |
record_format | invenio |
spelling | cern-6854962019-09-30T06:29:59Zhttp://cds.cern.ch/record/685496engMangin-Brinet, MClark, A GDonega, MD'Onofrio, MFerrère, DMikulec, BMoed, SWeber, MHartjes, FMuijs, SPeeters, SChouridou, SRoe, SWallny, RBernabeu, JLacasta, CFeld, LKetterer, CMeinhardt, JDolezal, ZKodys, PKubik, PReznicek, PAllport, P PDervan, P JGreenall, AJackson, J NJones, T JPhillips, P WSmith, N ASutcliffe, PTavera, MElectrical test results from ATLAS-SCT end-cap modulesDetectors and Experimental TechniquesThe LHC operating conditions present several challenges to the module performance of the ATLAS Semiconductor Tracker (SCT). This detector consists of four cylindrical barrel layers of silicon strip detectors and of 18 disks in the forward and backward direction. Four different module designs exist, one for the barrel and three (inner, middle and outer) for the rings of the disks. A series of several end-cap module pre-production prototypes of inner, middle and outer types have been built and extensively characterized on single module test benches in the institutes of the collaboration. The scope of this document is to summarize the electrical performance measurements made in laboratory on these end-cap module pre-production prototypes, with special emphasis on the result of electrical tests after irradiation. As summarized in the conclusion, the electrical performance specifications are met before irradiation, but are exceeded after an irradiation dose of $1.5.10^{14}$p/cm$^2$, that is a fluence corresponding to half the total dose ATLAS-SCT is foreseen to receive during its life time. Higher threshold operation will then be required with a corresponding expected loss in tracking efficiency.ATL-INDET-2003-004oai:cds.cern.ch:6854962003-05-18 |
spellingShingle | Detectors and Experimental Techniques Mangin-Brinet, M Clark, A G Donega, M D'Onofrio, M Ferrère, D Mikulec, B Moed, S Weber, M Hartjes, F Muijs, S Peeters, S Chouridou, S Roe, S Wallny, R Bernabeu, J Lacasta, C Feld, L Ketterer, C Meinhardt, J Dolezal, Z Kodys, P Kubik, P Reznicek, P Allport, P P Dervan, P J Greenall, A Jackson, J N Jones, T J Phillips, P W Smith, N A Sutcliffe, P Tavera, M Electrical test results from ATLAS-SCT end-cap modules |
title | Electrical test results from ATLAS-SCT end-cap modules |
title_full | Electrical test results from ATLAS-SCT end-cap modules |
title_fullStr | Electrical test results from ATLAS-SCT end-cap modules |
title_full_unstemmed | Electrical test results from ATLAS-SCT end-cap modules |
title_short | Electrical test results from ATLAS-SCT end-cap modules |
title_sort | electrical test results from atlas-sct end-cap modules |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/685496 |
work_keys_str_mv | AT manginbrinetm electricaltestresultsfromatlassctendcapmodules AT clarkag electricaltestresultsfromatlassctendcapmodules AT donegam electricaltestresultsfromatlassctendcapmodules AT donofriom electricaltestresultsfromatlassctendcapmodules AT ferrered electricaltestresultsfromatlassctendcapmodules AT mikulecb electricaltestresultsfromatlassctendcapmodules AT moeds electricaltestresultsfromatlassctendcapmodules AT weberm electricaltestresultsfromatlassctendcapmodules AT hartjesf electricaltestresultsfromatlassctendcapmodules AT muijss electricaltestresultsfromatlassctendcapmodules AT peeterss electricaltestresultsfromatlassctendcapmodules AT chouridous electricaltestresultsfromatlassctendcapmodules AT roes electricaltestresultsfromatlassctendcapmodules AT wallnyr electricaltestresultsfromatlassctendcapmodules AT bernabeuj electricaltestresultsfromatlassctendcapmodules AT lacastac electricaltestresultsfromatlassctendcapmodules AT feldl electricaltestresultsfromatlassctendcapmodules AT kettererc electricaltestresultsfromatlassctendcapmodules AT meinhardtj electricaltestresultsfromatlassctendcapmodules AT dolezalz electricaltestresultsfromatlassctendcapmodules AT kodysp electricaltestresultsfromatlassctendcapmodules AT kubikp electricaltestresultsfromatlassctendcapmodules AT reznicekp electricaltestresultsfromatlassctendcapmodules AT allportpp electricaltestresultsfromatlassctendcapmodules AT dervanpj electricaltestresultsfromatlassctendcapmodules AT greenalla electricaltestresultsfromatlassctendcapmodules AT jacksonjn electricaltestresultsfromatlassctendcapmodules AT jonestj electricaltestresultsfromatlassctendcapmodules AT phillipspw electricaltestresultsfromatlassctendcapmodules AT smithna electricaltestresultsfromatlassctendcapmodules AT sutcliffep electricaltestresultsfromatlassctendcapmodules AT taveram electricaltestresultsfromatlassctendcapmodules |