Performance of the Signal Vacuum Cables of the Liquid Argon Calorimeter Endcap Cryostat Signal Feedthroughs

This note presents of brief summary of the design specification and the performance under test of the signal vacuum cables which are used in the signal feedthroughs of the ATLAS liquid argon calorimeter endcap cryostats.

Detalles Bibliográficos
Autores principales: Axen, D A, Birney, P, Dowling, A, Dowling, A S, Fincke-Keeler, M, Hodges, T, Holness, F, Ince, T, Keeler, Richard K, Langstaf, R, Lefebvre, M, Lenckowski, M, Lindner, J, MacDonald, R, McDonald, R, Muzzeral, E, Poffenberger, P R, Van Uytven, J, Vowles, G, Wiggins, W
Lenguaje:eng
Publicado: 2003
Materias:
Acceso en línea:http://cds.cern.ch/record/685527
_version_ 1780901525913075712
author Axen, D A
Birney, P
Dowling, A
Dowling, A S
Fincke-Keeler, M
Hodges, T
Holness, F
Ince, T
Keeler, Richard K
Langstaf, R
Lefebvre, M
Lenckowski, M
Lindner, J
MacDonald, R
McDonald, R
Muzzeral, E
Poffenberger, P R
Van Uytven, J
Vowles, G
Wiggins, W
author_facet Axen, D A
Birney, P
Dowling, A
Dowling, A S
Fincke-Keeler, M
Hodges, T
Holness, F
Ince, T
Keeler, Richard K
Langstaf, R
Lefebvre, M
Lenckowski, M
Lindner, J
MacDonald, R
McDonald, R
Muzzeral, E
Poffenberger, P R
Van Uytven, J
Vowles, G
Wiggins, W
author_sort Axen, D A
collection CERN
description This note presents of brief summary of the design specification and the performance under test of the signal vacuum cables which are used in the signal feedthroughs of the ATLAS liquid argon calorimeter endcap cryostats.
id cern-685527
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2003
record_format invenio
spelling cern-6855272019-09-30T06:29:59Zhttp://cds.cern.ch/record/685527engAxen, D ABirney, PDowling, ADowling, A SFincke-Keeler, MHodges, THolness, FInce, TKeeler, Richard KLangstaf, RLefebvre, MLenckowski, MLindner, JMacDonald, RMcDonald, RMuzzeral, EPoffenberger, P RVan Uytven, JVowles, GWiggins, WPerformance of the Signal Vacuum Cables of the Liquid Argon Calorimeter Endcap Cryostat Signal FeedthroughsDetectors and Experimental TechniquesThis note presents of brief summary of the design specification and the performance under test of the signal vacuum cables which are used in the signal feedthroughs of the ATLAS liquid argon calorimeter endcap cryostats.ATL-LARG-2003-007ATL-AE-EN-0015oai:cds.cern.ch:6855272003-07-04
spellingShingle Detectors and Experimental Techniques
Axen, D A
Birney, P
Dowling, A
Dowling, A S
Fincke-Keeler, M
Hodges, T
Holness, F
Ince, T
Keeler, Richard K
Langstaf, R
Lefebvre, M
Lenckowski, M
Lindner, J
MacDonald, R
McDonald, R
Muzzeral, E
Poffenberger, P R
Van Uytven, J
Vowles, G
Wiggins, W
Performance of the Signal Vacuum Cables of the Liquid Argon Calorimeter Endcap Cryostat Signal Feedthroughs
title Performance of the Signal Vacuum Cables of the Liquid Argon Calorimeter Endcap Cryostat Signal Feedthroughs
title_full Performance of the Signal Vacuum Cables of the Liquid Argon Calorimeter Endcap Cryostat Signal Feedthroughs
title_fullStr Performance of the Signal Vacuum Cables of the Liquid Argon Calorimeter Endcap Cryostat Signal Feedthroughs
title_full_unstemmed Performance of the Signal Vacuum Cables of the Liquid Argon Calorimeter Endcap Cryostat Signal Feedthroughs
title_short Performance of the Signal Vacuum Cables of the Liquid Argon Calorimeter Endcap Cryostat Signal Feedthroughs
title_sort performance of the signal vacuum cables of the liquid argon calorimeter endcap cryostat signal feedthroughs
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/685527
work_keys_str_mv AT axenda performanceofthesignalvacuumcablesoftheliquidargoncalorimeterendcapcryostatsignalfeedthroughs
AT birneyp performanceofthesignalvacuumcablesoftheliquidargoncalorimeterendcapcryostatsignalfeedthroughs
AT dowlinga performanceofthesignalvacuumcablesoftheliquidargoncalorimeterendcapcryostatsignalfeedthroughs
AT dowlingas performanceofthesignalvacuumcablesoftheliquidargoncalorimeterendcapcryostatsignalfeedthroughs
AT finckekeelerm performanceofthesignalvacuumcablesoftheliquidargoncalorimeterendcapcryostatsignalfeedthroughs
AT hodgest performanceofthesignalvacuumcablesoftheliquidargoncalorimeterendcapcryostatsignalfeedthroughs
AT holnessf performanceofthesignalvacuumcablesoftheliquidargoncalorimeterendcapcryostatsignalfeedthroughs
AT incet performanceofthesignalvacuumcablesoftheliquidargoncalorimeterendcapcryostatsignalfeedthroughs
AT keelerrichardk performanceofthesignalvacuumcablesoftheliquidargoncalorimeterendcapcryostatsignalfeedthroughs
AT langstafr performanceofthesignalvacuumcablesoftheliquidargoncalorimeterendcapcryostatsignalfeedthroughs
AT lefebvrem performanceofthesignalvacuumcablesoftheliquidargoncalorimeterendcapcryostatsignalfeedthroughs
AT lenckowskim performanceofthesignalvacuumcablesoftheliquidargoncalorimeterendcapcryostatsignalfeedthroughs
AT lindnerj performanceofthesignalvacuumcablesoftheliquidargoncalorimeterendcapcryostatsignalfeedthroughs
AT macdonaldr performanceofthesignalvacuumcablesoftheliquidargoncalorimeterendcapcryostatsignalfeedthroughs
AT mcdonaldr performanceofthesignalvacuumcablesoftheliquidargoncalorimeterendcapcryostatsignalfeedthroughs
AT muzzerale performanceofthesignalvacuumcablesoftheliquidargoncalorimeterendcapcryostatsignalfeedthroughs
AT poffenbergerpr performanceofthesignalvacuumcablesoftheliquidargoncalorimeterendcapcryostatsignalfeedthroughs
AT vanuytvenj performanceofthesignalvacuumcablesoftheliquidargoncalorimeterendcapcryostatsignalfeedthroughs
AT vowlesg performanceofthesignalvacuumcablesoftheliquidargoncalorimeterendcapcryostatsignalfeedthroughs
AT wigginsw performanceofthesignalvacuumcablesoftheliquidargoncalorimeterendcapcryostatsignalfeedthroughs