Cargando…
Timing Measurements for the second Level Trigger software of ATLAS with TrigTimeAlgs
Timing measurements for the ATLAS LVL-2 trigger software performed with the TrigTimeAlgs package [1] were studied. The reproducibility of the latency of a typical algorithm was measured under constant conditions. The measuring procedure is described and a method is proposed to improve the reliabilit...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2003
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/685561 |
Sumario: | Timing measurements for the ATLAS LVL-2 trigger software performed with the TrigTimeAlgs package [1] were studied. The reproducibility of the latency of a typical algorithm was measured under constant conditions. The measuring procedure is described and a method is proposed to improve the reliability of timing measurements (minimum method). The results of timing measurements with the latest nightly release (08-28 2003) are shown. |
---|