Performance of the ATLA-A Silicon Detector with Analogue Read Out

The performace of an ATLAS-A silicon micro-strip detector prototype with FELIX 128 analogue read out chip has been studied. The noise level and the signal to noise ratio have been measured as a funtion of both detector bias and temperature. No evidence of micro-discharge was observed for detector bi...

Descripción completa

Detalles Bibliográficos
Autores principales: Allport, P.P., Booth, P.S.L., Green, C., Greenall, A., Hanlon, M., Jackson, John Neil, Jones, T.J., Richardson, J.D., Marti i Garcia, S., Parzefall, U., Sheridan, A.E., Smith, N.A.
Lenguaje:eng
Publicado: 1996
Materias:
Acceso en línea:http://cds.cern.ch/record/685981
_version_ 1780901617377214464
author Allport, P.P.
Booth, P.S.L.
Green, C.
Greenall, A.
Hanlon, M.
Jackson, John Neil
Jones, T.J.
Richardson, J.D.
Marti i Garcia, S.
Parzefall, U.
Sheridan, A.E.
Smith, N.A.
author_facet Allport, P.P.
Booth, P.S.L.
Green, C.
Greenall, A.
Hanlon, M.
Jackson, John Neil
Jones, T.J.
Richardson, J.D.
Marti i Garcia, S.
Parzefall, U.
Sheridan, A.E.
Smith, N.A.
author_sort Allport, P.P.
collection CERN
description The performace of an ATLAS-A silicon micro-strip detector prototype with FELIX 128 analogue read out chip has been studied. The noise level and the signal to noise ratio have been measured as a funtion of both detector bias and temperature. No evidence of micro-discharge was observed for detector bias voltages up to 300 V.
id cern-685981
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1996
record_format invenio
spelling cern-6859812023-03-14T18:53:44Zhttp://cds.cern.ch/record/685981engAllport, P.P.Booth, P.S.L.Green, C.Greenall, A.Hanlon, M.Jackson, John NeilJones, T.J.Richardson, J.D.Marti i Garcia, S.Parzefall, U.Sheridan, A.E.Smith, N.A.Performance of the ATLA-A Silicon Detector with Analogue Read OutDetectors and Experimental TechniquesThe performace of an ATLAS-A silicon micro-strip detector prototype with FELIX 128 analogue read out chip has been studied. The noise level and the signal to noise ratio have been measured as a funtion of both detector bias and temperature. No evidence of micro-discharge was observed for detector bias voltages up to 300 V.hep-ex/9606012ATL-I-PN-133oai:cds.cern.ch:6859811996-06-21
spellingShingle Detectors and Experimental Techniques
Allport, P.P.
Booth, P.S.L.
Green, C.
Greenall, A.
Hanlon, M.
Jackson, John Neil
Jones, T.J.
Richardson, J.D.
Marti i Garcia, S.
Parzefall, U.
Sheridan, A.E.
Smith, N.A.
Performance of the ATLA-A Silicon Detector with Analogue Read Out
title Performance of the ATLA-A Silicon Detector with Analogue Read Out
title_full Performance of the ATLA-A Silicon Detector with Analogue Read Out
title_fullStr Performance of the ATLA-A Silicon Detector with Analogue Read Out
title_full_unstemmed Performance of the ATLA-A Silicon Detector with Analogue Read Out
title_short Performance of the ATLA-A Silicon Detector with Analogue Read Out
title_sort performance of the atla-a silicon detector with analogue read out
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/685981
work_keys_str_mv AT allportpp performanceoftheatlaasilicondetectorwithanaloguereadout
AT boothpsl performanceoftheatlaasilicondetectorwithanaloguereadout
AT greenc performanceoftheatlaasilicondetectorwithanaloguereadout
AT greenalla performanceoftheatlaasilicondetectorwithanaloguereadout
AT hanlonm performanceoftheatlaasilicondetectorwithanaloguereadout
AT jacksonjohnneil performanceoftheatlaasilicondetectorwithanaloguereadout
AT jonestj performanceoftheatlaasilicondetectorwithanaloguereadout
AT richardsonjd performanceoftheatlaasilicondetectorwithanaloguereadout
AT martiigarcias performanceoftheatlaasilicondetectorwithanaloguereadout
AT parzefallu performanceoftheatlaasilicondetectorwithanaloguereadout
AT sheridanae performanceoftheatlaasilicondetectorwithanaloguereadout
AT smithna performanceoftheatlaasilicondetectorwithanaloguereadout