Cargando…
Cutting of Two Marble Dummy Crystals in Industrial Prototype Conditions
Two marble samples were cut to specified conditions with the tooling set designed for the mass processing of the 110'000 PbWO4 crystals of the CMS Electromagnetic Calorimeter. We wanted to test in particular the reproducibility of the electrical contact on the reference sphere, the accuracy of...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1997
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/686975 |
Sumario: | Two marble samples were cut to specified conditions with the tooling set designed for the mass processing of the 110'000 PbWO4 crystals of the CMS Electromagnetic Calorimeter. We wanted to test in particular the reproducibility of the electrical contact on the reference sphere, the accuracy of the new positioning tools at each cutting operation in their respective positions |
---|