Cargando…

Signal-to-Noise Evaluations for the CMS Silicon Microstrip Detectors

This note gathers the existing information on the parameters of the CMS silicon microstrip detectors, in order to compute the signal-to-noise ratio for different configurations. Both signal and noise are computed analytically, starting from laboratory measurements of the characteristic impedances of...

Descripción completa

Detalles Bibliográficos
Autor principal: Bozzi, Concezio
Lenguaje:eng
Publicado: 1997
Materias:
Acceso en línea:http://cds.cern.ch/record/686986
_version_ 1780901665113636864
author Bozzi, Concezio
author_facet Bozzi, Concezio
author_sort Bozzi, Concezio
collection CERN
description This note gathers the existing information on the parameters of the CMS silicon microstrip detectors, in order to compute the signal-to-noise ratio for different configurations. Both signal and noise are computed analytically, starting from laboratory measurements of the characteristic impedances of the detectors. Results are presented for a 50 micron strip pitch detector, read out every strip and every second strip, and for a 100 micron pitch detector read out every second strip.
id cern-686986
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1997
record_format invenio
spelling cern-6869862019-09-30T06:29:59Zhttp://cds.cern.ch/record/686986engBozzi, ConcezioSignal-to-Noise Evaluations for the CMS Silicon Microstrip DetectorsDetectors and Experimental TechniquesThis note gathers the existing information on the parameters of the CMS silicon microstrip detectors, in order to compute the signal-to-noise ratio for different configurations. Both signal and noise are computed analytically, starting from laboratory measurements of the characteristic impedances of the detectors. Results are presented for a 50 micron strip pitch detector, read out every strip and every second strip, and for a 100 micron pitch detector read out every second strip.CMS-NOTE-1997-026oai:cds.cern.ch:6869861997-04-25
spellingShingle Detectors and Experimental Techniques
Bozzi, Concezio
Signal-to-Noise Evaluations for the CMS Silicon Microstrip Detectors
title Signal-to-Noise Evaluations for the CMS Silicon Microstrip Detectors
title_full Signal-to-Noise Evaluations for the CMS Silicon Microstrip Detectors
title_fullStr Signal-to-Noise Evaluations for the CMS Silicon Microstrip Detectors
title_full_unstemmed Signal-to-Noise Evaluations for the CMS Silicon Microstrip Detectors
title_short Signal-to-Noise Evaluations for the CMS Silicon Microstrip Detectors
title_sort signal-to-noise evaluations for the cms silicon microstrip detectors
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/686986
work_keys_str_mv AT bozziconcezio signaltonoiseevaluationsforthecmssiliconmicrostripdetectors