Cargando…
Comparison of Electromagnetic Shower Profile in 1996 Test Beam and GEANT Simulation
The lateral dimensions of the electromagnetic shower in the lead tunsgtate ( PbWO4) crystals have been studied in 1996 test beam data and the results compared to the GEANT simulation. A set of events scanning across the crystal has been chosen and the shower containment in the central crystal has be...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
1998
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/687005 |
_version_ | 1780901668885364736 |
---|---|
author | Lassila-Perini, Kati |
author_facet | Lassila-Perini, Kati |
author_sort | Lassila-Perini, Kati |
collection | CERN |
description | The lateral dimensions of the electromagnetic shower in the lead tunsgtate ( PbWO4) crystals have been studied in 1996 test beam data and the results compared to the GEANT simulation. A set of events scanning across the crystal has been chosen and the shower containment in the central crystal has been studied as a function of the impact point on the crystal. It is shown that the simulation and the data agree fairly well, but the GEANT simulation has a tendency to overestimate he shower dimensions. A very good agreement is obtained if the lateral width of the GEANT shower is reduced by 6%. |
id | cern-687005 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1998 |
record_format | invenio |
spelling | cern-6870052019-09-30T06:29:59Zhttp://cds.cern.ch/record/687005engLassila-Perini, KatiComparison of Electromagnetic Shower Profile in 1996 Test Beam and GEANT SimulationDetectors and Experimental TechniquesThe lateral dimensions of the electromagnetic shower in the lead tunsgtate ( PbWO4) crystals have been studied in 1996 test beam data and the results compared to the GEANT simulation. A set of events scanning across the crystal has been chosen and the shower containment in the central crystal has been studied as a function of the impact point on the crystal. It is shown that the simulation and the data agree fairly well, but the GEANT simulation has a tendency to overestimate he shower dimensions. A very good agreement is obtained if the lateral width of the GEANT shower is reduced by 6%.CMS-NOTE-1998-031oai:cds.cern.ch:6870051998-06-03 |
spellingShingle | Detectors and Experimental Techniques Lassila-Perini, Kati Comparison of Electromagnetic Shower Profile in 1996 Test Beam and GEANT Simulation |
title | Comparison of Electromagnetic Shower Profile in 1996 Test Beam and GEANT Simulation |
title_full | Comparison of Electromagnetic Shower Profile in 1996 Test Beam and GEANT Simulation |
title_fullStr | Comparison of Electromagnetic Shower Profile in 1996 Test Beam and GEANT Simulation |
title_full_unstemmed | Comparison of Electromagnetic Shower Profile in 1996 Test Beam and GEANT Simulation |
title_short | Comparison of Electromagnetic Shower Profile in 1996 Test Beam and GEANT Simulation |
title_sort | comparison of electromagnetic shower profile in 1996 test beam and geant simulation |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/687005 |
work_keys_str_mv | AT lassilaperinikati comparisonofelectromagneticshowerprofilein1996testbeamandgeantsimulation |