CMS Level-1 Calorimeter Trigger Detailed Simulation
CMS level-1 calorimeter trigger simulation results are discussed. The simulation results are obtained using CMSIM version 111 program based on the GEANT simulation of the detector. These CMSIM results compare favorably to the results from our fast simulation program used in earlier studies. Both the...
Autores principales: | , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1998
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/687010 |
_version_ | 1780901670053478400 |
---|---|
author | Dasu, Sridhara Badgett, William Jaworski, Mathew Lackey, Joe Smith, Wesley H |
author_facet | Dasu, Sridhara Badgett, William Jaworski, Mathew Lackey, Joe Smith, Wesley H |
author_sort | Dasu, Sridhara |
collection | CERN |
description | CMS level-1 calorimeter trigger simulation results are discussed. The simulation results are obtained using CMSIM version 111 program based on the GEANT simulation of the detector. These CMSIM results compare favorably to the results from our fast simulation program used in earlier studies. Both these results indicate that the rate requirements of the data acquisition system can be met with a reasonable safety factor of three while providing high efficiencies for high ET physics processes of interest to CMS. |
id | cern-687010 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1998 |
record_format | invenio |
spelling | cern-6870102019-09-30T06:29:59Zhttp://cds.cern.ch/record/687010engDasu, SridharaBadgett, WilliamJaworski, MathewLackey, JoeSmith, Wesley HCMS Level-1 Calorimeter Trigger Detailed SimulationDetectors and Experimental TechniquesCMS level-1 calorimeter trigger simulation results are discussed. The simulation results are obtained using CMSIM version 111 program based on the GEANT simulation of the detector. These CMSIM results compare favorably to the results from our fast simulation program used in earlier studies. Both these results indicate that the rate requirements of the data acquisition system can be met with a reasonable safety factor of three while providing high efficiencies for high ET physics processes of interest to CMS.CMS-NOTE-1998-027oai:cds.cern.ch:6870101998-05-08 |
spellingShingle | Detectors and Experimental Techniques Dasu, Sridhara Badgett, William Jaworski, Mathew Lackey, Joe Smith, Wesley H CMS Level-1 Calorimeter Trigger Detailed Simulation |
title | CMS Level-1 Calorimeter Trigger Detailed Simulation |
title_full | CMS Level-1 Calorimeter Trigger Detailed Simulation |
title_fullStr | CMS Level-1 Calorimeter Trigger Detailed Simulation |
title_full_unstemmed | CMS Level-1 Calorimeter Trigger Detailed Simulation |
title_short | CMS Level-1 Calorimeter Trigger Detailed Simulation |
title_sort | cms level-1 calorimeter trigger detailed simulation |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/687010 |
work_keys_str_mv | AT dasusridhara cmslevel1calorimetertriggerdetailedsimulation AT badgettwilliam cmslevel1calorimetertriggerdetailedsimulation AT jaworskimathew cmslevel1calorimetertriggerdetailedsimulation AT lackeyjoe cmslevel1calorimetertriggerdetailedsimulation AT smithwesleyh cmslevel1calorimetertriggerdetailedsimulation |