Cargando…
Lateral Uniformity of Energy Response in the August 1997 ECAL Test Beam Matrix
The lateral uniformity of the energy response is studied using data taken in August 1997. After correcting for a calibration related error, present only in data taken in August and September 1997, the lateral uniformity is found to be excellent. The response as a function of position across the thre...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
1998
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/687016 |
_version_ | 1780901671388315648 |
---|---|
author | Seez, Christopher |
author_facet | Seez, Christopher |
author_sort | Seez, Christopher |
collection | CERN |
description | The lateral uniformity of the energy response is studied using data taken in August 1997. After correcting for a calibration related error, present only in data taken in August and September 1997, the lateral uniformity is found to be excellent. The response as a function of position across the three crystals studied is entirely regular and in agreement with the expected fluctuation in energy containment predicted by shower Monte Carlo. The linearity of response between 50 and 120 GeV is excellent. |
id | cern-687016 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1998 |
record_format | invenio |
spelling | cern-6870162019-09-30T06:29:59Zhttp://cds.cern.ch/record/687016engSeez, ChristopherLateral Uniformity of Energy Response in the August 1997 ECAL Test Beam MatrixDetectors and Experimental TechniquesThe lateral uniformity of the energy response is studied using data taken in August 1997. After correcting for a calibration related error, present only in data taken in August and September 1997, the lateral uniformity is found to be excellent. The response as a function of position across the three crystals studied is entirely regular and in agreement with the expected fluctuation in energy containment predicted by shower Monte Carlo. The linearity of response between 50 and 120 GeV is excellent.CMS-NOTE-1998-023oai:cds.cern.ch:6870161998-04-20 |
spellingShingle | Detectors and Experimental Techniques Seez, Christopher Lateral Uniformity of Energy Response in the August 1997 ECAL Test Beam Matrix |
title | Lateral Uniformity of Energy Response in the August 1997 ECAL Test Beam Matrix |
title_full | Lateral Uniformity of Energy Response in the August 1997 ECAL Test Beam Matrix |
title_fullStr | Lateral Uniformity of Energy Response in the August 1997 ECAL Test Beam Matrix |
title_full_unstemmed | Lateral Uniformity of Energy Response in the August 1997 ECAL Test Beam Matrix |
title_short | Lateral Uniformity of Energy Response in the August 1997 ECAL Test Beam Matrix |
title_sort | lateral uniformity of energy response in the august 1997 ecal test beam matrix |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/687016 |
work_keys_str_mv | AT seezchristopher lateraluniformityofenergyresponseintheaugust1997ecaltestbeammatrix |