Performance of Resistive Plate Chambers for the muon detection at CMS

The latest results, still preliminary, of tests dedicated to study the performance of Resistive Plate Chamber for the CMS experiment are presented. conditions of incident flux up to 2 Full efficiency with a 2 ns time resolution in kHz/cm2 has been obtained. Detector uniformity has been studied and f...

Descripción completa

Detalles Bibliográficos
Autores principales: Abbrescia, M, Altieri, S, Belli, G, Bruno, G, Colaleo, A, Gianini, G, Iaselli, G, Loddo, F, Maggi, M, Marangelli, B, Natali, S, Nuzzo, S, Pugliese, G, Ranieri, A, Ratti, S P, Romano, F, Viola, L, Vitulo, P
Lenguaje:eng
Publicado: 1998
Materias:
Acceso en línea:https://dx.doi.org/10.1016/S0920-5632(99)00528-9
http://cds.cern.ch/record/687053
Descripción
Sumario:The latest results, still preliminary, of tests dedicated to study the performance of Resistive Plate Chamber for the CMS experiment are presented. conditions of incident flux up to 2 Full efficiency with a 2 ns time resolution in kHz/cm2 has been obtained. Detector uniformity has been studied and found to be well within the constraints due to the large surfaces used in the experiment. An aging test is currently being carried out and shows no significant performance variation with time.