Cargando…

Performance of Resistive Plate Chambers for the muon detection at CMS

The latest results, still preliminary, of tests dedicated to study the performance of Resistive Plate Chamber for the CMS experiment are presented. conditions of incident flux up to 2 Full efficiency with a 2 ns time resolution in kHz/cm2 has been obtained. Detector uniformity has been studied and f...

Descripción completa

Detalles Bibliográficos
Autores principales: Abbrescia, M, Altieri, S, Belli, G, Bruno, G, Colaleo, A, Gianini, G, Iaselli, G, Loddo, F, Maggi, M, Marangelli, B, Natali, S, Nuzzo, S, Pugliese, G, Ranieri, A, Ratti, S P, Romano, F, Viola, L, Vitulo, P
Lenguaje:eng
Publicado: 1998
Materias:
Acceso en línea:https://dx.doi.org/10.1016/S0920-5632(99)00528-9
http://cds.cern.ch/record/687053
_version_ 1780901679104786432
author Abbrescia, M
Altieri, S
Belli, G
Bruno, G
Colaleo, A
Gianini, G
Iaselli, G
Loddo, F
Maggi, M
Marangelli, B
Natali, S
Nuzzo, S
Pugliese, G
Ranieri, A
Ratti, S P
Romano, F
Viola, L
Vitulo, P
author_facet Abbrescia, M
Altieri, S
Belli, G
Bruno, G
Colaleo, A
Gianini, G
Iaselli, G
Loddo, F
Maggi, M
Marangelli, B
Natali, S
Nuzzo, S
Pugliese, G
Ranieri, A
Ratti, S P
Romano, F
Viola, L
Vitulo, P
author_sort Abbrescia, M
collection CERN
description The latest results, still preliminary, of tests dedicated to study the performance of Resistive Plate Chamber for the CMS experiment are presented. conditions of incident flux up to 2 Full efficiency with a 2 ns time resolution in kHz/cm2 has been obtained. Detector uniformity has been studied and found to be well within the constraints due to the large surfaces used in the experiment. An aging test is currently being carried out and shows no significant performance variation with time.
id cern-687053
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1998
record_format invenio
spelling cern-6870532019-09-30T06:29:59Zdoi:10.1016/S0920-5632(99)00528-9http://cds.cern.ch/record/687053engAbbrescia, MAltieri, SBelli, GBruno, GColaleo, AGianini, GIaselli, GLoddo, FMaggi, MMarangelli, BNatali, SNuzzo, SPugliese, GRanieri, ARatti, S PRomano, FViola, LVitulo, PPerformance of Resistive Plate Chambers for the muon detection at CMSDetectors and Experimental TechniquesThe latest results, still preliminary, of tests dedicated to study the performance of Resistive Plate Chamber for the CMS experiment are presented. conditions of incident flux up to 2 Full efficiency with a 2 ns time resolution in kHz/cm2 has been obtained. Detector uniformity has been studied and found to be well within the constraints due to the large surfaces used in the experiment. An aging test is currently being carried out and shows no significant performance variation with time.CMS-CR-1998-024oai:cds.cern.ch:6870531998-12-17
spellingShingle Detectors and Experimental Techniques
Abbrescia, M
Altieri, S
Belli, G
Bruno, G
Colaleo, A
Gianini, G
Iaselli, G
Loddo, F
Maggi, M
Marangelli, B
Natali, S
Nuzzo, S
Pugliese, G
Ranieri, A
Ratti, S P
Romano, F
Viola, L
Vitulo, P
Performance of Resistive Plate Chambers for the muon detection at CMS
title Performance of Resistive Plate Chambers for the muon detection at CMS
title_full Performance of Resistive Plate Chambers for the muon detection at CMS
title_fullStr Performance of Resistive Plate Chambers for the muon detection at CMS
title_full_unstemmed Performance of Resistive Plate Chambers for the muon detection at CMS
title_short Performance of Resistive Plate Chambers for the muon detection at CMS
title_sort performance of resistive plate chambers for the muon detection at cms
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/S0920-5632(99)00528-9
http://cds.cern.ch/record/687053
work_keys_str_mv AT abbresciam performanceofresistiveplatechambersforthemuondetectionatcms
AT altieris performanceofresistiveplatechambersforthemuondetectionatcms
AT bellig performanceofresistiveplatechambersforthemuondetectionatcms
AT brunog performanceofresistiveplatechambersforthemuondetectionatcms
AT colaleoa performanceofresistiveplatechambersforthemuondetectionatcms
AT gianinig performanceofresistiveplatechambersforthemuondetectionatcms
AT iasellig performanceofresistiveplatechambersforthemuondetectionatcms
AT loddof performanceofresistiveplatechambersforthemuondetectionatcms
AT maggim performanceofresistiveplatechambersforthemuondetectionatcms
AT marangellib performanceofresistiveplatechambersforthemuondetectionatcms
AT natalis performanceofresistiveplatechambersforthemuondetectionatcms
AT nuzzos performanceofresistiveplatechambersforthemuondetectionatcms
AT puglieseg performanceofresistiveplatechambersforthemuondetectionatcms
AT ranieria performanceofresistiveplatechambersforthemuondetectionatcms
AT rattisp performanceofresistiveplatechambersforthemuondetectionatcms
AT romanof performanceofresistiveplatechambersforthemuondetectionatcms
AT violal performanceofresistiveplatechambersforthemuondetectionatcms
AT vitulop performanceofresistiveplatechambersforthemuondetectionatcms