Cargando…
Beam test results on n+ on n type silicon microstrip detectors before and after neutron irradiation
We present beam test results on AC-coupled, single-sided, n+ on n type silicon microstrip detectors. We have tested the detectors before and after irradiation at a fluence of 8.3E13 n/cm2, at different temperatures and bias voltages. The detectors signal-to-noise ratio, spatial resolution, charge co...
Autores principales: | Angarano, Matteo Maria, Bader, Attila, Creanza, Donato, Fiore, Luigi, Maggi, Giorgio, My, Salvatore, Radicci, Valeria, Raso, Giuseppe, Selvaggi, Giovanna, Silvestris, Lucia, Tempesta, Paolo, De Palma, Mauro |
---|---|
Lenguaje: | eng |
Publicado: |
1999
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/687104 |
Ejemplares similares
-
Test Beam Results on a Double-Sided Double-Metal Irradiated Microstrip Detector Before and After Neutron Irradiation
por: Angarano, Matteo Maria, et al.
Publicado: (1997) -
Characteristics and SPICE Simulation of a Single-Sided, n+ on n Si Strip Detector Before and After Neutron Irradiation
por: Angarano, Matteo Maria, et al.
Publicado: (1998) -
Signal-to-noise simulation of n+ on n type Si micro-strip detectors
por: Bader, Attila, et al.
Publicado: (1999) -
High Voltage Operation of heavily irradiated silicon microstrip detectors
por: Gu, W H, et al.
Publicado: (1999) -
Study of radiation damage and substrate resistivity effects from beam test of silicon microstrip detectors using LHC readout electronics
por: Angarano, Matteo Maria, et al.
Publicado: (2000)