Cargando…
Fine Calibration of Detector Positions by Tracks in Helsinki Silicon Beam Telescope
An efficient algorithm is presented to perform fine calibration of detector positions in a beam telescope. Data from Helsinki Silicon Beam Telescope ( SiBT) are used to demonstrate the performance of the algorithm. The intrinsic alignment precision obtained is better than 1 micrometer in location an...
Autores principales: | Heikkinen, A M, Karimäki, Veikko |
---|---|
Lenguaje: | eng |
Publicado: |
1999
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/687122 |