Cargando…
Test Beam Results on a Double-Sided Double-Metal Irradiated Microstrip Detector Before and After Neutron Irradiation
We present the results of beam tests carried out on an irradiated AC-coupled, poly biased, double-sided, double-metal silicon microstrip detector. The detector has been exposed to the beam at three subsequent times: before irradiation, right after irradiation and one year later, keeping it at 0 C. A...
Autores principales: | , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1997
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/687126 |
_version_ | 1780901693433577472 |
---|---|
author | Angarano, Matteo Maria Boemi, Davide Creanza, Donato Fiore, Luigi Maggi, Giorgio My, Salvatore Pompili, Alexis Raso, Giuseppe Selvaggi, Giovanna Silvestris, Lucia Tempesta, Paolo De Palma, Mauro |
author_facet | Angarano, Matteo Maria Boemi, Davide Creanza, Donato Fiore, Luigi Maggi, Giorgio My, Salvatore Pompili, Alexis Raso, Giuseppe Selvaggi, Giovanna Silvestris, Lucia Tempesta, Paolo De Palma, Mauro |
author_sort | Angarano, Matteo Maria |
collection | CERN |
description | We present the results of beam tests carried out on an irradiated AC-coupled, poly biased, double-sided, double-metal silicon microstrip detector. The detector has been exposed to the beam at three subsequent times: before irradiation, right after irradiation and one year later, keeping it at 0 C. A signal to noise ratio ( S/N) decrease has been observed on both sides and it can be interpreted in term of noise increase due to higher detector capacitance and leakage current after irradiation. The high efficiency characterizing the device has been preserved after irradiation, while a substantial stability of S/N and efficiency performances after one year, the detector being kept at 0 C, have been observed. |
id | cern-687126 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1997 |
record_format | invenio |
spelling | cern-6871262019-09-30T06:29:59Zhttp://cds.cern.ch/record/687126engAngarano, Matteo MariaBoemi, DavideCreanza, DonatoFiore, LuigiMaggi, GiorgioMy, SalvatorePompili, AlexisRaso, GiuseppeSelvaggi, GiovannaSilvestris, LuciaTempesta, PaoloDe Palma, MauroTest Beam Results on a Double-Sided Double-Metal Irradiated Microstrip Detector Before and After Neutron IrradiationDetectors and Experimental TechniquesWe present the results of beam tests carried out on an irradiated AC-coupled, poly biased, double-sided, double-metal silicon microstrip detector. The detector has been exposed to the beam at three subsequent times: before irradiation, right after irradiation and one year later, keeping it at 0 C. A signal to noise ratio ( S/N) decrease has been observed on both sides and it can be interpreted in term of noise increase due to higher detector capacitance and leakage current after irradiation. The high efficiency characterizing the device has been preserved after irradiation, while a substantial stability of S/N and efficiency performances after one year, the detector being kept at 0 C, have been observed.CMS-NOTE-1997-103oai:cds.cern.ch:6871261997-12-11 |
spellingShingle | Detectors and Experimental Techniques Angarano, Matteo Maria Boemi, Davide Creanza, Donato Fiore, Luigi Maggi, Giorgio My, Salvatore Pompili, Alexis Raso, Giuseppe Selvaggi, Giovanna Silvestris, Lucia Tempesta, Paolo De Palma, Mauro Test Beam Results on a Double-Sided Double-Metal Irradiated Microstrip Detector Before and After Neutron Irradiation |
title | Test Beam Results on a Double-Sided Double-Metal Irradiated Microstrip Detector Before and After Neutron Irradiation |
title_full | Test Beam Results on a Double-Sided Double-Metal Irradiated Microstrip Detector Before and After Neutron Irradiation |
title_fullStr | Test Beam Results on a Double-Sided Double-Metal Irradiated Microstrip Detector Before and After Neutron Irradiation |
title_full_unstemmed | Test Beam Results on a Double-Sided Double-Metal Irradiated Microstrip Detector Before and After Neutron Irradiation |
title_short | Test Beam Results on a Double-Sided Double-Metal Irradiated Microstrip Detector Before and After Neutron Irradiation |
title_sort | test beam results on a double-sided double-metal irradiated microstrip detector before and after neutron irradiation |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/687126 |
work_keys_str_mv | AT angaranomatteomaria testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation AT boemidavide testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation AT creanzadonato testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation AT fioreluigi testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation AT maggigiorgio testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation AT mysalvatore testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation AT pompilialexis testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation AT rasogiuseppe testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation AT selvaggigiovanna testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation AT silvestrislucia testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation AT tempestapaolo testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation AT depalmamauro testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation |