Cargando…

Test Beam Results on a Double-Sided Double-Metal Irradiated Microstrip Detector Before and After Neutron Irradiation

We present the results of beam tests carried out on an irradiated AC-coupled, poly biased, double-sided, double-metal silicon microstrip detector. The detector has been exposed to the beam at three subsequent times: before irradiation, right after irradiation and one year later, keeping it at 0 C. A...

Descripción completa

Detalles Bibliográficos
Autores principales: Angarano, Matteo Maria, Boemi, Davide, Creanza, Donato, Fiore, Luigi, Maggi, Giorgio, My, Salvatore, Pompili, Alexis, Raso, Giuseppe, Selvaggi, Giovanna, Silvestris, Lucia, Tempesta, Paolo, De Palma, Mauro
Lenguaje:eng
Publicado: 1997
Materias:
Acceso en línea:http://cds.cern.ch/record/687126
_version_ 1780901693433577472
author Angarano, Matteo Maria
Boemi, Davide
Creanza, Donato
Fiore, Luigi
Maggi, Giorgio
My, Salvatore
Pompili, Alexis
Raso, Giuseppe
Selvaggi, Giovanna
Silvestris, Lucia
Tempesta, Paolo
De Palma, Mauro
author_facet Angarano, Matteo Maria
Boemi, Davide
Creanza, Donato
Fiore, Luigi
Maggi, Giorgio
My, Salvatore
Pompili, Alexis
Raso, Giuseppe
Selvaggi, Giovanna
Silvestris, Lucia
Tempesta, Paolo
De Palma, Mauro
author_sort Angarano, Matteo Maria
collection CERN
description We present the results of beam tests carried out on an irradiated AC-coupled, poly biased, double-sided, double-metal silicon microstrip detector. The detector has been exposed to the beam at three subsequent times: before irradiation, right after irradiation and one year later, keeping it at 0 C. A signal to noise ratio ( S/N) decrease has been observed on both sides and it can be interpreted in term of noise increase due to higher detector capacitance and leakage current after irradiation. The high efficiency characterizing the device has been preserved after irradiation, while a substantial stability of S/N and efficiency performances after one year, the detector being kept at 0 C, have been observed.
id cern-687126
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1997
record_format invenio
spelling cern-6871262019-09-30T06:29:59Zhttp://cds.cern.ch/record/687126engAngarano, Matteo MariaBoemi, DavideCreanza, DonatoFiore, LuigiMaggi, GiorgioMy, SalvatorePompili, AlexisRaso, GiuseppeSelvaggi, GiovannaSilvestris, LuciaTempesta, PaoloDe Palma, MauroTest Beam Results on a Double-Sided Double-Metal Irradiated Microstrip Detector Before and After Neutron IrradiationDetectors and Experimental TechniquesWe present the results of beam tests carried out on an irradiated AC-coupled, poly biased, double-sided, double-metal silicon microstrip detector. The detector has been exposed to the beam at three subsequent times: before irradiation, right after irradiation and one year later, keeping it at 0 C. A signal to noise ratio ( S/N) decrease has been observed on both sides and it can be interpreted in term of noise increase due to higher detector capacitance and leakage current after irradiation. The high efficiency characterizing the device has been preserved after irradiation, while a substantial stability of S/N and efficiency performances after one year, the detector being kept at 0 C, have been observed.CMS-NOTE-1997-103oai:cds.cern.ch:6871261997-12-11
spellingShingle Detectors and Experimental Techniques
Angarano, Matteo Maria
Boemi, Davide
Creanza, Donato
Fiore, Luigi
Maggi, Giorgio
My, Salvatore
Pompili, Alexis
Raso, Giuseppe
Selvaggi, Giovanna
Silvestris, Lucia
Tempesta, Paolo
De Palma, Mauro
Test Beam Results on a Double-Sided Double-Metal Irradiated Microstrip Detector Before and After Neutron Irradiation
title Test Beam Results on a Double-Sided Double-Metal Irradiated Microstrip Detector Before and After Neutron Irradiation
title_full Test Beam Results on a Double-Sided Double-Metal Irradiated Microstrip Detector Before and After Neutron Irradiation
title_fullStr Test Beam Results on a Double-Sided Double-Metal Irradiated Microstrip Detector Before and After Neutron Irradiation
title_full_unstemmed Test Beam Results on a Double-Sided Double-Metal Irradiated Microstrip Detector Before and After Neutron Irradiation
title_short Test Beam Results on a Double-Sided Double-Metal Irradiated Microstrip Detector Before and After Neutron Irradiation
title_sort test beam results on a double-sided double-metal irradiated microstrip detector before and after neutron irradiation
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/687126
work_keys_str_mv AT angaranomatteomaria testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation
AT boemidavide testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation
AT creanzadonato testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation
AT fioreluigi testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation
AT maggigiorgio testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation
AT mysalvatore testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation
AT pompilialexis testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation
AT rasogiuseppe testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation
AT selvaggigiovanna testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation
AT silvestrislucia testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation
AT tempestapaolo testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation
AT depalmamauro testbeamresultsonadoublesideddoublemetalirradiatedmicrostripdetectorbeforeandafterneutronirradiation