Cargando…
The performance of RPCs with bakelite electrodes of various resistivity under high radiation fluxes
Three medium-size RPCs with bakelite electrodes having resistivity of 5*10**8 Ohm*cm, 5*10**9 Ohm*cm and 3*10**10 Ohm*cm were tested in the Gamma Irradiation Facility at CERN in 1997, 1998 and 1999. The 2 mm gap modules working in an Inverted Double Gap configuration filled with gas mixtures contain...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/687199 |
_version_ | 1780901708665192448 |
---|---|
author | Cwiok, M Dominik, Wojciech Górski, M Królikowski, J |
author_facet | Cwiok, M Dominik, Wojciech Górski, M Królikowski, J |
author_sort | Cwiok, M |
collection | CERN |
description | Three medium-size RPCs with bakelite electrodes having resistivity of 5*10**8 Ohm*cm, 5*10**9 Ohm*cm and 3*10**10 Ohm*cm were tested in the Gamma Irradiation Facility at CERN in 1997, 1998 and 1999. The 2 mm gap modules working in an Inverted Double Gap configuration filled with gas mixtures containing freon C2H2F4 and operated in avalanche mode exhibit wide efficiency plateau, good time resolution and small time walk due to rate variation even at intensities as high as 1 kHz/cm**2/gap of a continuous radiation flux. |
id | cern-687199 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2000 |
record_format | invenio |
spelling | cern-6871992019-09-30T06:29:59Zhttp://cds.cern.ch/record/687199engCwiok, MDominik, WojciechGórski, MKrólikowski, JThe performance of RPCs with bakelite electrodes of various resistivity under high radiation fluxesDetectors and Experimental TechniquesThree medium-size RPCs with bakelite electrodes having resistivity of 5*10**8 Ohm*cm, 5*10**9 Ohm*cm and 3*10**10 Ohm*cm were tested in the Gamma Irradiation Facility at CERN in 1997, 1998 and 1999. The 2 mm gap modules working in an Inverted Double Gap configuration filled with gas mixtures containing freon C2H2F4 and operated in avalanche mode exhibit wide efficiency plateau, good time resolution and small time walk due to rate variation even at intensities as high as 1 kHz/cm**2/gap of a continuous radiation flux.CMS-CR-2000-003oai:cds.cern.ch:6871992000-01-20 |
spellingShingle | Detectors and Experimental Techniques Cwiok, M Dominik, Wojciech Górski, M Królikowski, J The performance of RPCs with bakelite electrodes of various resistivity under high radiation fluxes |
title | The performance of RPCs with bakelite electrodes of various resistivity under high radiation fluxes |
title_full | The performance of RPCs with bakelite electrodes of various resistivity under high radiation fluxes |
title_fullStr | The performance of RPCs with bakelite electrodes of various resistivity under high radiation fluxes |
title_full_unstemmed | The performance of RPCs with bakelite electrodes of various resistivity under high radiation fluxes |
title_short | The performance of RPCs with bakelite electrodes of various resistivity under high radiation fluxes |
title_sort | performance of rpcs with bakelite electrodes of various resistivity under high radiation fluxes |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/687199 |
work_keys_str_mv | AT cwiokm theperformanceofrpcswithbakeliteelectrodesofvariousresistivityunderhighradiationfluxes AT dominikwojciech theperformanceofrpcswithbakeliteelectrodesofvariousresistivityunderhighradiationfluxes AT gorskim theperformanceofrpcswithbakeliteelectrodesofvariousresistivityunderhighradiationfluxes AT krolikowskij theperformanceofrpcswithbakeliteelectrodesofvariousresistivityunderhighradiationfluxes AT cwiokm performanceofrpcswithbakeliteelectrodesofvariousresistivityunderhighradiationfluxes AT dominikwojciech performanceofrpcswithbakeliteelectrodesofvariousresistivityunderhighradiationfluxes AT gorskim performanceofrpcswithbakeliteelectrodesofvariousresistivityunderhighradiationfluxes AT krolikowskij performanceofrpcswithbakeliteelectrodesofvariousresistivityunderhighradiationfluxes |