Cargando…
PYTHIA-GEANT Calculation of Resolutions and Reconstruction Efficiencies in an Fe HF Calorimeter
The energy resolution, the eta and phi resolutions, and the 1-TeV jet reconstruction efficiency in an Fe-filled HF calorimeter are calculated using PYTHIA+GEANT for a mean number of 25 minimum-bias ( MB) events on top of each jet, and for four transerve segmentations: Deta = Dphi= 0.10, 0.20, 0.30 a...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/687203 |
_version_ | 1780901709521879040 |
---|---|
author | CERN. Geneva |
author_facet | CERN. Geneva |
author_sort | CERN. Geneva |
collection | CERN |
description | The energy resolution, the eta and phi resolutions, and the 1-TeV jet reconstruction efficiency in an Fe-filled HF calorimeter are calculated using PYTHIA+GEANT for a mean number of 25 minimum-bias ( MB) events on top of each jet, and for four transerve segmentations: Deta = Dphi= 0.10, 0.20, 0.30 and 0.40. The jet reconstruction efficiency for an [eta,phi] segmentation of 0.20 is 94.1+/-0.8% at a MB rejection of 99.7%; the energy resolution is 21.3+/-0.2%; and, the angular resolutions are 0.032+/-.001 in eta and 0.018+/-.001 in phi. |
id | cern-687203 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2000 |
record_format | invenio |
spelling | cern-6872032019-09-30T06:29:59Zhttp://cds.cern.ch/record/687203engCERN. GenevaPYTHIA-GEANT Calculation of Resolutions and Reconstruction Efficiencies in an Fe HF CalorimeterDetectors and Experimental TechniquesThe energy resolution, the eta and phi resolutions, and the 1-TeV jet reconstruction efficiency in an Fe-filled HF calorimeter are calculated using PYTHIA+GEANT for a mean number of 25 minimum-bias ( MB) events on top of each jet, and for four transerve segmentations: Deta = Dphi= 0.10, 0.20, 0.30 and 0.40. The jet reconstruction efficiency for an [eta,phi] segmentation of 0.20 is 94.1+/-0.8% at a MB rejection of 99.7%; the energy resolution is 21.3+/-0.2%; and, the angular resolutions are 0.032+/-.001 in eta and 0.018+/-.001 in phi.CMS-NOTE-2000-004oai:cds.cern.ch:6872032000-01-31 |
spellingShingle | Detectors and Experimental Techniques CERN. Geneva PYTHIA-GEANT Calculation of Resolutions and Reconstruction Efficiencies in an Fe HF Calorimeter |
title | PYTHIA-GEANT Calculation of Resolutions and Reconstruction Efficiencies in an Fe HF Calorimeter |
title_full | PYTHIA-GEANT Calculation of Resolutions and Reconstruction Efficiencies in an Fe HF Calorimeter |
title_fullStr | PYTHIA-GEANT Calculation of Resolutions and Reconstruction Efficiencies in an Fe HF Calorimeter |
title_full_unstemmed | PYTHIA-GEANT Calculation of Resolutions and Reconstruction Efficiencies in an Fe HF Calorimeter |
title_short | PYTHIA-GEANT Calculation of Resolutions and Reconstruction Efficiencies in an Fe HF Calorimeter |
title_sort | pythia-geant calculation of resolutions and reconstruction efficiencies in an fe hf calorimeter |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/687203 |
work_keys_str_mv | AT cerngeneva pythiageantcalculationofresolutionsandreconstructionefficienciesinanfehfcalorimeter |