Cargando…
Tests on 1999 Vacuum Photodiodes for the CMS Ecal Endcaps
The permormance of fifty-five, one inch about 25 mm diameter Vacuum Phototriodes ( VPT) has been studied and twenty-five have been selected for CERN test beam runs. VPT paramaters measured over a range of bias voltages are: anode and photocurrent dark currents, photocathode response, DC current gain...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/687216 |
_version_ | 1780901712169533440 |
---|---|
author | Camanzi, Barbara Ergun, G Hubson, P R Imrie, Derek C |
author_facet | Camanzi, Barbara Ergun, G Hubson, P R Imrie, Derek C |
author_sort | Camanzi, Barbara |
collection | CERN |
description | The permormance of fifty-five, one inch about 25 mm diameter Vacuum Phototriodes ( VPT) has been studied and twenty-five have been selected for CERN test beam runs. VPT paramaters measured over a range of bias voltages are: anode and photocurrent dark currents, photocathode response, DC current gain, and the ratio of the pulse gain in a 4.7T axial magnetic field to the corresponding pulse gain in zero field. |
id | cern-687216 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2000 |
record_format | invenio |
spelling | cern-6872162019-09-30T06:29:59Zhttp://cds.cern.ch/record/687216engCamanzi, BarbaraErgun, GHubson, P RImrie, Derek CTests on 1999 Vacuum Photodiodes for the CMS Ecal EndcapsDetectors and Experimental TechniquesThe permormance of fifty-five, one inch about 25 mm diameter Vacuum Phototriodes ( VPT) has been studied and twenty-five have been selected for CERN test beam runs. VPT paramaters measured over a range of bias voltages are: anode and photocurrent dark currents, photocathode response, DC current gain, and the ratio of the pulse gain in a 4.7T axial magnetic field to the corresponding pulse gain in zero field.CMS-NOTE-2000-010oai:cds.cern.ch:6872162000-02-03 |
spellingShingle | Detectors and Experimental Techniques Camanzi, Barbara Ergun, G Hubson, P R Imrie, Derek C Tests on 1999 Vacuum Photodiodes for the CMS Ecal Endcaps |
title | Tests on 1999 Vacuum Photodiodes for the CMS Ecal Endcaps |
title_full | Tests on 1999 Vacuum Photodiodes for the CMS Ecal Endcaps |
title_fullStr | Tests on 1999 Vacuum Photodiodes for the CMS Ecal Endcaps |
title_full_unstemmed | Tests on 1999 Vacuum Photodiodes for the CMS Ecal Endcaps |
title_short | Tests on 1999 Vacuum Photodiodes for the CMS Ecal Endcaps |
title_sort | tests on 1999 vacuum photodiodes for the cms ecal endcaps |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/687216 |
work_keys_str_mv | AT camanzibarbara testson1999vacuumphotodiodesforthecmsecalendcaps AT ergung testson1999vacuumphotodiodesforthecmsecalendcaps AT hubsonpr testson1999vacuumphotodiodesforthecmsecalendcaps AT imriederekc testson1999vacuumphotodiodesforthecmsecalendcaps |