Cargando…
Test Results of a Phi Monitoring System
The development and tests of a Phi monitoring system prototype designed for the CMS Muon Spectrometer alignment are described. The system, using a sweeping laser beam, defines a light reference plane to be used for the continuous monitoring of the Muon detectors. The performance of the system in the...
Autores principales: | , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1997
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/687230 |
_version_ | 1780901714861228032 |
---|---|
author | Figueroa, Carlos Alberdi, Javier Burgos, C Ferrrando, A Matorras, Francisco Molinero, Antonio Rodriguo, T Shvachkin, V |
author_facet | Figueroa, Carlos Alberdi, Javier Burgos, C Ferrrando, A Matorras, Francisco Molinero, Antonio Rodriguo, T Shvachkin, V |
author_sort | Figueroa, Carlos |
collection | CERN |
description | The development and tests of a Phi monitoring system prototype designed for the CMS Muon Spectrometer alignment are described. The system, using a sweeping laser beam, defines a light reference plane to be used for the continuous monitoring of the Muon detectors. The performance of the system in the Laboratory was satisfactory. It showed good stability and linearity response behaviour. With the appropriate selection of components it can monitor large range position shifts ( up to 1-2 cm) with good accuracy at long distances ( ~ 60 mu accuracy at 10 m). |
id | cern-687230 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1997 |
record_format | invenio |
spelling | cern-6872302019-09-30T06:29:59Zhttp://cds.cern.ch/record/687230engFigueroa, CarlosAlberdi, JavierBurgos, CFerrrando, AMatorras, FranciscoMolinero, AntonioRodriguo, TShvachkin, VTest Results of a Phi Monitoring SystemDetectors and Experimental TechniquesThe development and tests of a Phi monitoring system prototype designed for the CMS Muon Spectrometer alignment are described. The system, using a sweeping laser beam, defines a light reference plane to be used for the continuous monitoring of the Muon detectors. The performance of the system in the Laboratory was satisfactory. It showed good stability and linearity response behaviour. With the appropriate selection of components it can monitor large range position shifts ( up to 1-2 cm) with good accuracy at long distances ( ~ 60 mu accuracy at 10 m).CMS-NOTE-1997-005oai:cds.cern.ch:6872301997-01-19 |
spellingShingle | Detectors and Experimental Techniques Figueroa, Carlos Alberdi, Javier Burgos, C Ferrrando, A Matorras, Francisco Molinero, Antonio Rodriguo, T Shvachkin, V Test Results of a Phi Monitoring System |
title | Test Results of a Phi Monitoring System |
title_full | Test Results of a Phi Monitoring System |
title_fullStr | Test Results of a Phi Monitoring System |
title_full_unstemmed | Test Results of a Phi Monitoring System |
title_short | Test Results of a Phi Monitoring System |
title_sort | test results of a phi monitoring system |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/687230 |
work_keys_str_mv | AT figueroacarlos testresultsofaphimonitoringsystem AT alberdijavier testresultsofaphimonitoringsystem AT burgosc testresultsofaphimonitoringsystem AT ferrrandoa testresultsofaphimonitoringsystem AT matorrasfrancisco testresultsofaphimonitoringsystem AT molineroantonio testresultsofaphimonitoringsystem AT rodriguot testresultsofaphimonitoringsystem AT shvachkinv testresultsofaphimonitoringsystem |