Cargando…
The Effect of Tracker Material on The Level-1 Electromagnetic Trigger
The performance of the CMS Level-1 electromagnetic trigger simulation is investigated with incident electrons. The strong variation of tracker material as a function of eta causes a strong variation in the threshold required to achieve 95% efficiency. It is proposed to apply a scaling to the Level-1...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/687238 |
_version_ | 1780901716155170816 |
---|---|
author | Seez, Christopher |
author_facet | Seez, Christopher |
author_sort | Seez, Christopher |
collection | CERN |
description | The performance of the CMS Level-1 electromagnetic trigger simulation is investigated with incident electrons. The strong variation of tracker material as a function of eta causes a strong variation in the threshold required to achieve 95% efficiency. It is proposed to apply a scaling to the Level-1 electromagnetic trigger sums as a function of eta to produce a flat response. The effect of such a scaling on the Level-1 trigger rates is investigated. A set of rescaling constants is derived. |
id | cern-687238 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2000 |
record_format | invenio |
spelling | cern-6872382019-09-30T06:29:59Zhttp://cds.cern.ch/record/687238engSeez, ChristopherThe Effect of Tracker Material on The Level-1 Electromagnetic TriggerDetectors and Experimental TechniquesThe performance of the CMS Level-1 electromagnetic trigger simulation is investigated with incident electrons. The strong variation of tracker material as a function of eta causes a strong variation in the threshold required to achieve 95% efficiency. It is proposed to apply a scaling to the Level-1 electromagnetic trigger sums as a function of eta to produce a flat response. The effect of such a scaling on the Level-1 trigger rates is investigated. A set of rescaling constants is derived.CMS-NOTE-2000-031oai:cds.cern.ch:6872382000-04-17 |
spellingShingle | Detectors and Experimental Techniques Seez, Christopher The Effect of Tracker Material on The Level-1 Electromagnetic Trigger |
title | The Effect of Tracker Material on The Level-1 Electromagnetic Trigger |
title_full | The Effect of Tracker Material on The Level-1 Electromagnetic Trigger |
title_fullStr | The Effect of Tracker Material on The Level-1 Electromagnetic Trigger |
title_full_unstemmed | The Effect of Tracker Material on The Level-1 Electromagnetic Trigger |
title_short | The Effect of Tracker Material on The Level-1 Electromagnetic Trigger |
title_sort | effect of tracker material on the level-1 electromagnetic trigger |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/687238 |
work_keys_str_mv | AT seezchristopher theeffectoftrackermaterialonthelevel1electromagnetictrigger AT seezchristopher effectoftrackermaterialonthelevel1electromagnetictrigger |