Cargando…
ECAL Barrel Intercalibration at Low Luminosity
The purpose of this study is to give the order of magnitude of the time necessary to intercalibrate barrel crystals when LHC starts with a very low luminosity ( 10E-32 cm-2s-1). In this note, we will examine the use of isolated electromagnetic clusters from pi0 or eta or other photon and electron so...
Autores principales: | , |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/687246 |
_version_ | 1780901717907341312 |
---|---|
author | Martin, Franck Pansart, Jean-Pierre |
author_facet | Martin, Franck Pansart, Jean-Pierre |
author_sort | Martin, Franck |
collection | CERN |
description | The purpose of this study is to give the order of magnitude of the time necessary to intercalibrate barrel crystals when LHC starts with a very low luminosity ( 10E-32 cm-2s-1). In this note, we will examine the use of isolated electromagnetic clusters from pi0 or eta or other photon and electron sources. This study does not use the mass reconstruction of the particle ( pi0, eta, ...). It is based on the intercalibration of crystals which belong to a same pseudorapidity interval, assuming that the crystal deposited energy distributions are independent of the azimuth phi. |
id | cern-687246 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2000 |
record_format | invenio |
spelling | cern-6872462019-09-30T06:29:59Zhttp://cds.cern.ch/record/687246engMartin, FranckPansart, Jean-PierreECAL Barrel Intercalibration at Low LuminosityDetectors and Experimental TechniquesThe purpose of this study is to give the order of magnitude of the time necessary to intercalibrate barrel crystals when LHC starts with a very low luminosity ( 10E-32 cm-2s-1). In this note, we will examine the use of isolated electromagnetic clusters from pi0 or eta or other photon and electron sources. This study does not use the mass reconstruction of the particle ( pi0, eta, ...). It is based on the intercalibration of crystals which belong to a same pseudorapidity interval, assuming that the crystal deposited energy distributions are independent of the azimuth phi.CMS-NOTE-2000-033oai:cds.cern.ch:6872462000-05-11 |
spellingShingle | Detectors and Experimental Techniques Martin, Franck Pansart, Jean-Pierre ECAL Barrel Intercalibration at Low Luminosity |
title | ECAL Barrel Intercalibration at Low Luminosity |
title_full | ECAL Barrel Intercalibration at Low Luminosity |
title_fullStr | ECAL Barrel Intercalibration at Low Luminosity |
title_full_unstemmed | ECAL Barrel Intercalibration at Low Luminosity |
title_short | ECAL Barrel Intercalibration at Low Luminosity |
title_sort | ecal barrel intercalibration at low luminosity |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/687246 |
work_keys_str_mv | AT martinfranck ecalbarrelintercalibrationatlowluminosity AT pansartjeanpierre ecalbarrelintercalibrationatlowluminosity |