Deflection of the Alveolar Crystal Support Structures in the CMS ECAL Endcap Calorimeter

The results of a series of Finite Element Analyses are presented for the deflections under load of the alveolar units proposed to support the ECAL Endcap crystals. The analyses were carried out in 1997 and have been used to predict the strength of the current alveolar unit design. The current design...

Descripción completa

Detalles Bibliográficos
Autores principales: Fell, B, Cockerill, David J A, Greenhalgh, Justin
Lenguaje:eng
Publicado: 2000
Materias:
Acceso en línea:http://cds.cern.ch/record/687265
_version_ 1780901722207551488
author Fell, B
Cockerill, David J A
Greenhalgh, Justin
author_facet Fell, B
Cockerill, David J A
Greenhalgh, Justin
author_sort Fell, B
collection CERN
description The results of a series of Finite Element Analyses are presented for the deflections under load of the alveolar units proposed to support the ECAL Endcap crystals. The analyses were carried out in 1997 and have been used to predict the strength of the current alveolar unit design. The current design, with a 5x5 array and 30x30 mm2 crystals, is predicted to have a deflection of 13 microns under gravitational load, which is within the target design of 30 microns.
id cern-687265
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2000
record_format invenio
spelling cern-6872652019-09-30T06:29:59Zhttp://cds.cern.ch/record/687265engFell, BCockerill, David J AGreenhalgh, JustinDeflection of the Alveolar Crystal Support Structures in the CMS ECAL Endcap CalorimeterDetectors and Experimental TechniquesThe results of a series of Finite Element Analyses are presented for the deflections under load of the alveolar units proposed to support the ECAL Endcap crystals. The analyses were carried out in 1997 and have been used to predict the strength of the current alveolar unit design. The current design, with a 5x5 array and 30x30 mm2 crystals, is predicted to have a deflection of 13 microns under gravitational load, which is within the target design of 30 microns.CMS-NOTE-2000-048oai:cds.cern.ch:6872652000-07-24
spellingShingle Detectors and Experimental Techniques
Fell, B
Cockerill, David J A
Greenhalgh, Justin
Deflection of the Alveolar Crystal Support Structures in the CMS ECAL Endcap Calorimeter
title Deflection of the Alveolar Crystal Support Structures in the CMS ECAL Endcap Calorimeter
title_full Deflection of the Alveolar Crystal Support Structures in the CMS ECAL Endcap Calorimeter
title_fullStr Deflection of the Alveolar Crystal Support Structures in the CMS ECAL Endcap Calorimeter
title_full_unstemmed Deflection of the Alveolar Crystal Support Structures in the CMS ECAL Endcap Calorimeter
title_short Deflection of the Alveolar Crystal Support Structures in the CMS ECAL Endcap Calorimeter
title_sort deflection of the alveolar crystal support structures in the cms ecal endcap calorimeter
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/687265
work_keys_str_mv AT fellb deflectionofthealveolarcrystalsupportstructuresinthecmsecalendcapcalorimeter
AT cockerilldavidja deflectionofthealveolarcrystalsupportstructuresinthecmsecalendcapcalorimeter
AT greenhalghjustin deflectionofthealveolarcrystalsupportstructuresinthecmsecalendcapcalorimeter