Cargando…
Test-Beam Results on <100> Silicon Prototype Detectors with APV6 Front-End Chip Readout
Results are presented using data collected during the X5 test-beam performed in August 1999. To achieve a good estimate of signal and noise values, the raw data are processed off-line by a dedicated reconstruction program. In particular, an efficient algorithm for pedestal, noise and common mode cal...
Autores principales: | , |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/687267 |
_version_ | 1780901722643759104 |
---|---|
author | Winkler, Matthias Braibant, S |
author_facet | Winkler, Matthias Braibant, S |
author_sort | Winkler, Matthias |
collection | CERN |
description | Results are presented using data collected during the X5 test-beam performed in August 1999. To achieve a good estimate of signal and noise values, the raw data are processed off-line by a dedicated reconstruction program. In particular, an efficient algorithm for pedestal, noise and common mode calculation was developed and tested. The intrinsic performances of an AC-coupled CMS silicon micro-strip multi-geometry prototype detector, with a <100> crystal orientation and a low resistivity ( 1~k Omega cm), are investigated. This detector was exposed to an irradiation fluence of 3 imes10^{14} p/cm ^2 , equivalent to 10 years of operation at LHC. The signal-to-noise ratio and the ghost rates per strip and per cm ^2 are presented, as a function of the bias voltage. |
id | cern-687267 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2000 |
record_format | invenio |
spelling | cern-6872672019-09-30T06:29:59Zhttp://cds.cern.ch/record/687267engWinkler, MatthiasBraibant, STest-Beam Results on <100> Silicon Prototype Detectors with APV6 Front-End Chip ReadoutDetectors and Experimental TechniquesResults are presented using data collected during the X5 test-beam performed in August 1999. To achieve a good estimate of signal and noise values, the raw data are processed off-line by a dedicated reconstruction program. In particular, an efficient algorithm for pedestal, noise and common mode calculation was developed and tested. The intrinsic performances of an AC-coupled CMS silicon micro-strip multi-geometry prototype detector, with a <100> crystal orientation and a low resistivity ( 1~k Omega cm), are investigated. This detector was exposed to an irradiation fluence of 3 imes10^{14} p/cm ^2 , equivalent to 10 years of operation at LHC. The signal-to-noise ratio and the ghost rates per strip and per cm ^2 are presented, as a function of the bias voltage.CMS-NOTE-2000-050oai:cds.cern.ch:6872672000-08-21 |
spellingShingle | Detectors and Experimental Techniques Winkler, Matthias Braibant, S Test-Beam Results on <100> Silicon Prototype Detectors with APV6 Front-End Chip Readout |
title | Test-Beam Results on <100> Silicon Prototype Detectors with APV6 Front-End Chip Readout |
title_full | Test-Beam Results on <100> Silicon Prototype Detectors with APV6 Front-End Chip Readout |
title_fullStr | Test-Beam Results on <100> Silicon Prototype Detectors with APV6 Front-End Chip Readout |
title_full_unstemmed | Test-Beam Results on <100> Silicon Prototype Detectors with APV6 Front-End Chip Readout |
title_short | Test-Beam Results on <100> Silicon Prototype Detectors with APV6 Front-End Chip Readout |
title_sort | test-beam results on <100> silicon prototype detectors with apv6 front-end chip readout |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/687267 |
work_keys_str_mv | AT winklermatthias testbeamresultsonlt100gtsiliconprototypedetectorswithapv6frontendchipreadout AT braibants testbeamresultsonlt100gtsiliconprototypedetectorswithapv6frontendchipreadout |