Cargando…

Test-Beam Results on <100> Silicon Prototype Detectors with APV6 Front-End Chip Readout

Results are presented using data collected during the X5 test-beam performed in August 1999. To achieve a good estimate of signal and noise values, the raw data are processed off-line by a dedicated reconstruction program. In particular, an efficient algorithm for pedestal, noise and common mode cal...

Descripción completa

Detalles Bibliográficos
Autores principales: Winkler, Matthias, Braibant, S
Lenguaje:eng
Publicado: 2000
Materias:
Acceso en línea:http://cds.cern.ch/record/687267
_version_ 1780901722643759104
author Winkler, Matthias
Braibant, S
author_facet Winkler, Matthias
Braibant, S
author_sort Winkler, Matthias
collection CERN
description Results are presented using data collected during the X5 test-beam performed in August 1999. To achieve a good estimate of signal and noise values, the raw data are processed off-line by a dedicated reconstruction program. In particular, an efficient algorithm for pedestal, noise and common mode calculation was developed and tested. The intrinsic performances of an AC-coupled CMS silicon micro-strip multi-geometry prototype detector, with a <100> crystal orientation and a low resistivity ( 1~k Omega cm), are investigated. This detector was exposed to an irradiation fluence of 3 imes10^{14} p/cm ^2 , equivalent to 10 years of operation at LHC. The signal-to-noise ratio and the ghost rates per strip and per cm ^2 are presented, as a function of the bias voltage.
id cern-687267
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2000
record_format invenio
spelling cern-6872672019-09-30T06:29:59Zhttp://cds.cern.ch/record/687267engWinkler, MatthiasBraibant, STest-Beam Results on <100> Silicon Prototype Detectors with APV6 Front-End Chip ReadoutDetectors and Experimental TechniquesResults are presented using data collected during the X5 test-beam performed in August 1999. To achieve a good estimate of signal and noise values, the raw data are processed off-line by a dedicated reconstruction program. In particular, an efficient algorithm for pedestal, noise and common mode calculation was developed and tested. The intrinsic performances of an AC-coupled CMS silicon micro-strip multi-geometry prototype detector, with a <100> crystal orientation and a low resistivity ( 1~k Omega cm), are investigated. This detector was exposed to an irradiation fluence of 3 imes10^{14} p/cm ^2 , equivalent to 10 years of operation at LHC. The signal-to-noise ratio and the ghost rates per strip and per cm ^2 are presented, as a function of the bias voltage.CMS-NOTE-2000-050oai:cds.cern.ch:6872672000-08-21
spellingShingle Detectors and Experimental Techniques
Winkler, Matthias
Braibant, S
Test-Beam Results on <100> Silicon Prototype Detectors with APV6 Front-End Chip Readout
title Test-Beam Results on <100> Silicon Prototype Detectors with APV6 Front-End Chip Readout
title_full Test-Beam Results on <100> Silicon Prototype Detectors with APV6 Front-End Chip Readout
title_fullStr Test-Beam Results on <100> Silicon Prototype Detectors with APV6 Front-End Chip Readout
title_full_unstemmed Test-Beam Results on <100> Silicon Prototype Detectors with APV6 Front-End Chip Readout
title_short Test-Beam Results on <100> Silicon Prototype Detectors with APV6 Front-End Chip Readout
title_sort test-beam results on <100> silicon prototype detectors with apv6 front-end chip readout
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/687267
work_keys_str_mv AT winklermatthias testbeamresultsonlt100gtsiliconprototypedetectorswithapv6frontendchipreadout
AT braibants testbeamresultsonlt100gtsiliconprototypedetectorswithapv6frontendchipreadout