Cargando…

Investigation of the charge collection for strongly irradiated Silicon strip detectors of the CMS ECAL Preshower

Strongly irradiated silicon strip detectors of different size, thickness and different design options were tested in a muon beam at CERN in 1999. A charge collection efficiency in excess of 85% and a signal to noise ratio of 6 are obtained in all cases at high enough bias voltage. Details of the cha...

Descripción completa

Detalles Bibliográficos
Autor principal: CERN. Geneva
Lenguaje:eng
Publicado: 2000
Materias:
Acceso en línea:http://cds.cern.ch/record/687283
_version_ 1780901725698260992
author CERN. Geneva
author_facet CERN. Geneva
author_sort CERN. Geneva
collection CERN
description Strongly irradiated silicon strip detectors of different size, thickness and different design options were tested in a muon beam at CERN in 1999. A charge collection efficiency in excess of 85% and a signal to noise ratio of 6 are obtained in all cases at high enough bias voltage. Details of the charge collection in the inter-strip and the guard ring region and crosstalk between strips were also studied. We find that the charge collection efficiency and the cross talk between strips depend on the interstrip distance.
id cern-687283
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2000
record_format invenio
spelling cern-6872832019-09-30T06:29:59Zhttp://cds.cern.ch/record/687283engCERN. GenevaInvestigation of the charge collection for strongly irradiated Silicon strip detectors of the CMS ECAL PreshowerDetectors and Experimental TechniquesStrongly irradiated silicon strip detectors of different size, thickness and different design options were tested in a muon beam at CERN in 1999. A charge collection efficiency in excess of 85% and a signal to noise ratio of 6 are obtained in all cases at high enough bias voltage. Details of the charge collection in the inter-strip and the guard ring region and crosstalk between strips were also studied. We find that the charge collection efficiency and the cross talk between strips depend on the interstrip distance.CMS-NOTE-2000-062oai:cds.cern.ch:6872832000-10-18
spellingShingle Detectors and Experimental Techniques
CERN. Geneva
Investigation of the charge collection for strongly irradiated Silicon strip detectors of the CMS ECAL Preshower
title Investigation of the charge collection for strongly irradiated Silicon strip detectors of the CMS ECAL Preshower
title_full Investigation of the charge collection for strongly irradiated Silicon strip detectors of the CMS ECAL Preshower
title_fullStr Investigation of the charge collection for strongly irradiated Silicon strip detectors of the CMS ECAL Preshower
title_full_unstemmed Investigation of the charge collection for strongly irradiated Silicon strip detectors of the CMS ECAL Preshower
title_short Investigation of the charge collection for strongly irradiated Silicon strip detectors of the CMS ECAL Preshower
title_sort investigation of the charge collection for strongly irradiated silicon strip detectors of the cms ecal preshower
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/687283
work_keys_str_mv AT cerngeneva investigationofthechargecollectionforstronglyirradiatedsiliconstripdetectorsofthecmsecalpreshower