Cargando…

Simulation of the baseline RPC trigger system for CMS: Efficiency and Output Rates in Single Muon Topology

This document contains a comprehensive set of results obtained in a simulation study of the performance of the baseline CMS RPC trigger system stand-alone. Single muon trigger efficiency and output rates are reported. The contribution to the output rate from muons produced at the vertex of the appar...

Descripción completa

Detalles Bibliográficos
Autores principales: Bruno, Giacomo, Konecki, Marcin
Lenguaje:eng
Publicado: 2001
Materias:
Acceso en línea:http://cds.cern.ch/record/687321
_version_ 1780901733432557568
author Bruno, Giacomo
Konecki, Marcin
author_facet Bruno, Giacomo
Konecki, Marcin
author_sort Bruno, Giacomo
collection CERN
description This document contains a comprehensive set of results obtained in a simulation study of the performance of the baseline CMS RPC trigger system stand-alone. Single muon trigger efficiency and output rates are reported. The contribution to the output rate from muons produced at the vertex of the apparatus, muons from hadron decays and accidental triggers are considered. The RPC system geometry version implemented in CMSIM 118 has been used. The RPC detector response has been simulated in a realistic way that includes the full timing chain, efficiency, cluster size and intrinsic noise. Streamers have not been simulated. Uncorrelated hits due to thermal neutrons, which are expected to be the main source of physical background in CMS, have been included in the simulation. Having in mind the experimentally measured values of the RPC characteristics, the system proves to be efficient enough, b ut its output rate turns out to be very sensitive to the cluster size and above all the contribution to it due to false triggers caused by the RPC intrinsic noise is unacceptably high in the barrel region.
id cern-687321
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2001
record_format invenio
spelling cern-6873212019-09-30T06:29:59Zhttp://cds.cern.ch/record/687321engBruno, GiacomoKonecki, MarcinSimulation of the baseline RPC trigger system for CMS: Efficiency and Output Rates in Single Muon TopologyDetectors and Experimental TechniquesThis document contains a comprehensive set of results obtained in a simulation study of the performance of the baseline CMS RPC trigger system stand-alone. Single muon trigger efficiency and output rates are reported. The contribution to the output rate from muons produced at the vertex of the apparatus, muons from hadron decays and accidental triggers are considered. The RPC system geometry version implemented in CMSIM 118 has been used. The RPC detector response has been simulated in a realistic way that includes the full timing chain, efficiency, cluster size and intrinsic noise. Streamers have not been simulated. Uncorrelated hits due to thermal neutrons, which are expected to be the main source of physical background in CMS, have been included in the simulation. Having in mind the experimentally measured values of the RPC characteristics, the system proves to be efficient enough, b ut its output rate turns out to be very sensitive to the cluster size and above all the contribution to it due to false triggers caused by the RPC intrinsic noise is unacceptably high in the barrel region.CMS-NOTE-2001-012oai:cds.cern.ch:6873212001-03-20
spellingShingle Detectors and Experimental Techniques
Bruno, Giacomo
Konecki, Marcin
Simulation of the baseline RPC trigger system for CMS: Efficiency and Output Rates in Single Muon Topology
title Simulation of the baseline RPC trigger system for CMS: Efficiency and Output Rates in Single Muon Topology
title_full Simulation of the baseline RPC trigger system for CMS: Efficiency and Output Rates in Single Muon Topology
title_fullStr Simulation of the baseline RPC trigger system for CMS: Efficiency and Output Rates in Single Muon Topology
title_full_unstemmed Simulation of the baseline RPC trigger system for CMS: Efficiency and Output Rates in Single Muon Topology
title_short Simulation of the baseline RPC trigger system for CMS: Efficiency and Output Rates in Single Muon Topology
title_sort simulation of the baseline rpc trigger system for cms: efficiency and output rates in single muon topology
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/687321
work_keys_str_mv AT brunogiacomo simulationofthebaselinerpctriggersystemforcmsefficiencyandoutputratesinsinglemuontopology
AT koneckimarcin simulationofthebaselinerpctriggersystemforcmsefficiencyandoutputratesinsinglemuontopology