Effect of Temperature Variation and Gas Composition on the Stability of the RPC Operation
An Inverted Double Gap RPC made of bakelite of 5*10^9 Ohm*cm volume resistivity was tested at avalanche rates up to 1 kHz/cm^2/gap in the Gamma Irradiation Facility at CERN in 2001. The inner surfaces of the chamber electrodes were cladded using linseed oil varnish. Dependence of the intrinsic RPC n...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2002
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/687394 |
_version_ | 1780901747225526272 |
---|---|
author | Cwiok, M Dominik, Wojciech Górski, M Królikowski, J |
author_facet | Cwiok, M Dominik, Wojciech Górski, M Królikowski, J |
author_sort | Cwiok, M |
collection | CERN |
description | An Inverted Double Gap RPC made of bakelite of 5*10^9 Ohm*cm volume resistivity was tested at avalanche rates up to 1 kHz/cm^2/gap in the Gamma Irradiation Facility at CERN in 2001. The inner surfaces of the chamber electrodes were cladded using linseed oil varnish. Dependence of the intrinsic RPC noise and the stability of the gas gain on the gas temperature and the gas composition are discussed. |
id | cern-687394 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2002 |
record_format | invenio |
spelling | cern-6873942019-09-30T06:29:59Zhttp://cds.cern.ch/record/687394engCwiok, MDominik, WojciechGórski, MKrólikowski, JEffect of Temperature Variation and Gas Composition on the Stability of the RPC OperationDetectors and Experimental TechniquesAn Inverted Double Gap RPC made of bakelite of 5*10^9 Ohm*cm volume resistivity was tested at avalanche rates up to 1 kHz/cm^2/gap in the Gamma Irradiation Facility at CERN in 2001. The inner surfaces of the chamber electrodes were cladded using linseed oil varnish. Dependence of the intrinsic RPC noise and the stability of the gas gain on the gas temperature and the gas composition are discussed.CMS-CR-2002-002oai:cds.cern.ch:6873942002-01-16 |
spellingShingle | Detectors and Experimental Techniques Cwiok, M Dominik, Wojciech Górski, M Królikowski, J Effect of Temperature Variation and Gas Composition on the Stability of the RPC Operation |
title | Effect of Temperature Variation and Gas Composition on the Stability of the RPC Operation |
title_full | Effect of Temperature Variation and Gas Composition on the Stability of the RPC Operation |
title_fullStr | Effect of Temperature Variation and Gas Composition on the Stability of the RPC Operation |
title_full_unstemmed | Effect of Temperature Variation and Gas Composition on the Stability of the RPC Operation |
title_short | Effect of Temperature Variation and Gas Composition on the Stability of the RPC Operation |
title_sort | effect of temperature variation and gas composition on the stability of the rpc operation |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/687394 |
work_keys_str_mv | AT cwiokm effectoftemperaturevariationandgascompositiononthestabilityoftherpcoperation AT dominikwojciech effectoftemperaturevariationandgascompositiononthestabilityoftherpcoperation AT gorskim effectoftemperaturevariationandgascompositiononthestabilityoftherpcoperation AT krolikowskij effectoftemperaturevariationandgascompositiononthestabilityoftherpcoperation |