Study of Calorimeter Calibration with Tau's in CMS.

We propose to calibrate in situ the CMS calorimetry using the single, isolated pions from tau-> pi nu in W -> tau nu and Z, gamma^* -> tau tau processes applying the p/E method. In case of pions non-interacting in the ECAL the method is straightforward, but for pions interacting...

Descripción completa

Detalles Bibliográficos
Autores principales: Denegri, Daniel, Kinnunen, Ritva, Nikitenko, Alexander
Lenguaje:eng
Publicado: 1997
Materias:
Acceso en línea:http://cds.cern.ch/record/687543
_version_ 1780901774424539136
author Denegri, Daniel
Kinnunen, Ritva
Nikitenko, Alexander
author_facet Denegri, Daniel
Kinnunen, Ritva
Nikitenko, Alexander
author_sort Denegri, Daniel
collection CERN
description We propose to calibrate in situ the CMS calorimetry using the single, isolated pions from tau-> pi nu in W -> tau nu and Z, gamma^* -> tau tau processes applying the p/E method. In case of pions non-interacting in the ECAL the method is straightforward, but for pions interacting in the ECAL care is needed to suppress and keep under control pi+- pi0's from tau's or QCS jets, which could vitiate the method. This can be achieved exploiting the ECAL granularity and tracker-calorimetry special matching. The momentum of the isolated high pt pion can be directly compared to the calorimeter measurement. Triggering of the W -> tau nu events is envisaged with a special tau-jet trigger combined with a missing transverse energy trigger. The Z gamma^* -> tau tau events could be triggered by lepton + tau-jet and double tau-jet trigger. The event rate for pt of pion > 15 GeV is e nough to calibrate each HCAL cell at a 1% precision after collection of 10^4 pb-1 of data.
id cern-687543
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1997
record_format invenio
spelling cern-6875432019-09-30T06:29:59Zhttp://cds.cern.ch/record/687543engDenegri, DanielKinnunen, RitvaNikitenko, AlexanderStudy of Calorimeter Calibration with Tau's in CMS.Detectors and Experimental TechniquesWe propose to calibrate in situ the CMS calorimetry using the single, isolated pions from tau-> pi nu in W -> tau nu and Z, gamma^* -> tau tau processes applying the p/E method. In case of pions non-interacting in the ECAL the method is straightforward, but for pions interacting in the ECAL care is needed to suppress and keep under control pi+- pi0's from tau's or QCS jets, which could vitiate the method. This can be achieved exploiting the ECAL granularity and tracker-calorimetry special matching. The momentum of the isolated high pt pion can be directly compared to the calorimeter measurement. Triggering of the W -> tau nu events is envisaged with a special tau-jet trigger combined with a missing transverse energy trigger. The Z gamma^* -> tau tau events could be triggered by lepton + tau-jet and double tau-jet trigger. The event rate for pt of pion > 15 GeV is e nough to calibrate each HCAL cell at a 1% precision after collection of 10^4 pb-1 of data.CMS-NOTE-1997-039oai:cds.cern.ch:6875431997-05-21
spellingShingle Detectors and Experimental Techniques
Denegri, Daniel
Kinnunen, Ritva
Nikitenko, Alexander
Study of Calorimeter Calibration with Tau's in CMS.
title Study of Calorimeter Calibration with Tau's in CMS.
title_full Study of Calorimeter Calibration with Tau's in CMS.
title_fullStr Study of Calorimeter Calibration with Tau's in CMS.
title_full_unstemmed Study of Calorimeter Calibration with Tau's in CMS.
title_short Study of Calorimeter Calibration with Tau's in CMS.
title_sort study of calorimeter calibration with tau's in cms.
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/687543
work_keys_str_mv AT denegridaniel studyofcalorimetercalibrationwithtausincms
AT kinnunenritva studyofcalorimetercalibrationwithtausincms
AT nikitenkoalexander studyofcalorimetercalibrationwithtausincms