Cargando…
Effect of the tracker cables on the photon resolution in CMS ECAL - (formerly issued as TN 96-101)
The effect of the tracker cables going through the gap between the tracker and the electromagnetic calorimeter has been studied. Three different cable arrangements have been investigated using 85 GeV photons at nu=1.25. The optimal solution is when the cables are uniformly distributed and placed as...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
1996
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/687546 |
_version_ | 1780901774871232512 |
---|---|
author | Lassila-Perini, Kati |
author_facet | Lassila-Perini, Kati |
author_sort | Lassila-Perini, Kati |
collection | CERN |
description | The effect of the tracker cables going through the gap between the tracker and the electromagnetic calorimeter has been studied. Three different cable arrangements have been investigated using 85 GeV photons at nu=1.25. The optimal solution is when the cables are uniformly distributed and placed as close as possible to the electromagnetic calorimeter . |
id | cern-687546 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1996 |
record_format | invenio |
spelling | cern-6875462019-09-30T06:29:59Zhttp://cds.cern.ch/record/687546engLassila-Perini, KatiEffect of the tracker cables on the photon resolution in CMS ECAL - (formerly issued as TN 96-101)Detectors and Experimental TechniquesThe effect of the tracker cables going through the gap between the tracker and the electromagnetic calorimeter has been studied. Three different cable arrangements have been investigated using 85 GeV photons at nu=1.25. The optimal solution is when the cables are uniformly distributed and placed as close as possible to the electromagnetic calorimeter .CMS-NOTE-1996-001oai:cds.cern.ch:6875461996-10-14 |
spellingShingle | Detectors and Experimental Techniques Lassila-Perini, Kati Effect of the tracker cables on the photon resolution in CMS ECAL - (formerly issued as TN 96-101) |
title | Effect of the tracker cables on the photon resolution in CMS ECAL - (formerly issued as TN 96-101) |
title_full | Effect of the tracker cables on the photon resolution in CMS ECAL - (formerly issued as TN 96-101) |
title_fullStr | Effect of the tracker cables on the photon resolution in CMS ECAL - (formerly issued as TN 96-101) |
title_full_unstemmed | Effect of the tracker cables on the photon resolution in CMS ECAL - (formerly issued as TN 96-101) |
title_short | Effect of the tracker cables on the photon resolution in CMS ECAL - (formerly issued as TN 96-101) |
title_sort | effect of the tracker cables on the photon resolution in cms ecal - (formerly issued as tn 96-101) |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/687546 |
work_keys_str_mv | AT lassilaperinikati effectofthetrackercablesonthephotonresolutionincmsecalformerlyissuedastn96101 |