Cargando…

Longitudinal Uniformity Scans of PbWO4 Crystals Using 120 GeV Electrons in the H4 Testbeam in 1997

During April and September 1997 data were taken in the H4 testbeam with electrons incident on the side faces ( i.e. perpendicular to the crystal axis) of lead tungstate crystals in order to extract detailed measurements of the longitudinal crystal light collection uniformities. Results are presented...

Descripción completa

Detalles Bibliográficos
Autores principales: Davies, Gavin, Barney, David, Petteni, M
Lenguaje:eng
Publicado: 1998
Materias:
Acceso en línea:http://cds.cern.ch/record/687582
_version_ 1780901781239234560
author Davies, Gavin
Barney, David
Petteni, M
author_facet Davies, Gavin
Barney, David
Petteni, M
author_sort Davies, Gavin
collection CERN
description During April and September 1997 data were taken in the H4 testbeam with electrons incident on the side faces ( i.e. perpendicular to the crystal axis) of lead tungstate crystals in order to extract detailed measurements of the longitudinal crystal light collection uniformities. Results are presented for 35 crystals ( five central rows in the 7x7 matrix) with 120 GeV incident electrons. The data were corrected for geometrical effects using a GEANT simulation. The effect of the measured uniformity curves on the ECAL energy resolution was calculated and compared with that predicted from the uniformity curves measured previously at PSI. Both the H4 and PSI data were used to predict the energy resolution constant term and these predictions were compared to the constant term measured directly in H4.
id cern-687582
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1998
record_format invenio
spelling cern-6875822019-09-30T06:29:59Zhttp://cds.cern.ch/record/687582engDavies, GavinBarney, DavidPetteni, MLongitudinal Uniformity Scans of PbWO4 Crystals Using 120 GeV Electrons in the H4 Testbeam in 1997Detectors and Experimental TechniquesDuring April and September 1997 data were taken in the H4 testbeam with electrons incident on the side faces ( i.e. perpendicular to the crystal axis) of lead tungstate crystals in order to extract detailed measurements of the longitudinal crystal light collection uniformities. Results are presented for 35 crystals ( five central rows in the 7x7 matrix) with 120 GeV incident electrons. The data were corrected for geometrical effects using a GEANT simulation. The effect of the measured uniformity curves on the ECAL energy resolution was calculated and compared with that predicted from the uniformity curves measured previously at PSI. Both the H4 and PSI data were used to predict the energy resolution constant term and these predictions were compared to the constant term measured directly in H4.CMS-NOTE-1998-057oai:cds.cern.ch:6875821998-10-08
spellingShingle Detectors and Experimental Techniques
Davies, Gavin
Barney, David
Petteni, M
Longitudinal Uniformity Scans of PbWO4 Crystals Using 120 GeV Electrons in the H4 Testbeam in 1997
title Longitudinal Uniformity Scans of PbWO4 Crystals Using 120 GeV Electrons in the H4 Testbeam in 1997
title_full Longitudinal Uniformity Scans of PbWO4 Crystals Using 120 GeV Electrons in the H4 Testbeam in 1997
title_fullStr Longitudinal Uniformity Scans of PbWO4 Crystals Using 120 GeV Electrons in the H4 Testbeam in 1997
title_full_unstemmed Longitudinal Uniformity Scans of PbWO4 Crystals Using 120 GeV Electrons in the H4 Testbeam in 1997
title_short Longitudinal Uniformity Scans of PbWO4 Crystals Using 120 GeV Electrons in the H4 Testbeam in 1997
title_sort longitudinal uniformity scans of pbwo4 crystals using 120 gev electrons in the h4 testbeam in 1997
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/687582
work_keys_str_mv AT daviesgavin longitudinaluniformityscansofpbwo4crystalsusing120gevelectronsintheh4testbeamin1997
AT barneydavid longitudinaluniformityscansofpbwo4crystalsusing120gevelectronsintheh4testbeamin1997
AT pettenim longitudinaluniformityscansofpbwo4crystalsusing120gevelectronsintheh4testbeamin1997