Cargando…

New SPS cooling system: "The day after"

During the shutdown from November 2000 until May 2001, major modifications of the cooling system of SPS have been carried out in the frame of the refurbishment and restructuring of the water network on CERN sites (Water Project). Since the new configuration is based on a closed circuit loop, the mos...

Descripción completa

Detalles Bibliográficos
Autores principales: Arduini, Gianluigi, Nonis, M
Lenguaje:eng
Publicado: 2002
Materias:
XX
Acceso en línea:http://cds.cern.ch/record/687613
_version_ 1780901787848409088
author Arduini, Gianluigi
Nonis, M
author_facet Arduini, Gianluigi
Nonis, M
author_sort Arduini, Gianluigi
collection CERN
description During the shutdown from November 2000 until May 2001, major modifications of the cooling system of SPS have been carried out in the frame of the refurbishment and restructuring of the water network on CERN sites (Water Project). Since the new configuration is based on a closed circuit loop, the most important consequence is the increase of the cooling water temperature from 11°C to a reference temperature of 25°C on the primary circuit. After a brief overview of the performance statistics in 2001 of the new cooling system, a preliminary analysis of the impact of the new temperature working point will be given. Special attention will be focused on those aspects that proved to be critical for reliable equipment operation as well as on the observed consequences on reproducibility of machine parameters and finally the capability of the system for future expansions. Recommendations and possible improvements will also be outlined.
id cern-687613
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2002
record_format invenio
spelling cern-6876132022-03-04T14:22:50Zhttp://cds.cern.ch/record/687613engArduini, GianluigiNonis, MNew SPS cooling system: "The day after"XXDuring the shutdown from November 2000 until May 2001, major modifications of the cooling system of SPS have been carried out in the frame of the refurbishment and restructuring of the water network on CERN sites (Water Project). Since the new configuration is based on a closed circuit loop, the most important consequence is the increase of the cooling water temperature from 11°C to a reference temperature of 25°C on the primary circuit. After a brief overview of the performance statistics in 2001 of the new cooling system, a preliminary analysis of the impact of the new temperature working point will be given. Special attention will be focused on those aspects that proved to be critical for reliable equipment operation as well as on the observed consequences on reproducibility of machine parameters and finally the capability of the system for future expansions. Recommendations and possible improvements will also be outlined.ST-Note-2002-004-CVoai:cds.cern.ch:6876132002-11-12
spellingShingle XX
Arduini, Gianluigi
Nonis, M
New SPS cooling system: "The day after"
title New SPS cooling system: "The day after"
title_full New SPS cooling system: "The day after"
title_fullStr New SPS cooling system: "The day after"
title_full_unstemmed New SPS cooling system: "The day after"
title_short New SPS cooling system: "The day after"
title_sort new sps cooling system: "the day after"
topic XX
url http://cds.cern.ch/record/687613
work_keys_str_mv AT arduinigianluigi newspscoolingsystemthedayafter
AT nonism newspscoolingsystemthedayafter