Cargando…
Thermal analysis of the ATLAS dump system
The dump system of the ATLAS Magnet, situated on third level of the USA15 cavern is an assembly of diodes and dump resistors through which the energy stored in the Magnet is dissipated when running down the magnet current to zero. The dump system is permanently connected to the Magnet through a syst...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2003
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/687629 |
_version_ | 1780901791126257664 |
---|---|
author | Wichrowska Polok, I |
author_facet | Wichrowska Polok, I |
author_sort | Wichrowska Polok, I |
collection | CERN |
description | The dump system of the ATLAS Magnet, situated on third level of the USA15 cavern is an assembly of diodes and dump resistors through which the energy stored in the Magnet is dissipated when running down the magnet current to zero. The dump system is permanently connected to the Magnet through a system of bus bars and is able to dissipate about 1.5 GJ of energy in 3 hours. The goal of this thermal analysis, performed by ST/CV, is to understand whether the heat released by the dump system can be removed by free convection into the PX15 shaft or if forced ventilation is needed |
id | cern-687629 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2003 |
record_format | invenio |
spelling | cern-6876292019-09-30T06:29:59Zhttp://cds.cern.ch/record/687629engWichrowska Polok, IThermal analysis of the ATLAS dump systemDetectors and Experimental TechniquesThe dump system of the ATLAS Magnet, situated on third level of the USA15 cavern is an assembly of diodes and dump resistors through which the energy stored in the Magnet is dissipated when running down the magnet current to zero. The dump system is permanently connected to the Magnet through a system of bus bars and is able to dissipate about 1.5 GJ of energy in 3 hours. The goal of this thermal analysis, performed by ST/CV, is to understand whether the heat released by the dump system can be removed by free convection into the PX15 shaft or if forced ventilation is neededST-Note-2003-005-CVoai:cds.cern.ch:6876292003-03-20 |
spellingShingle | Detectors and Experimental Techniques Wichrowska Polok, I Thermal analysis of the ATLAS dump system |
title | Thermal analysis of the ATLAS dump system |
title_full | Thermal analysis of the ATLAS dump system |
title_fullStr | Thermal analysis of the ATLAS dump system |
title_full_unstemmed | Thermal analysis of the ATLAS dump system |
title_short | Thermal analysis of the ATLAS dump system |
title_sort | thermal analysis of the atlas dump system |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/687629 |
work_keys_str_mv | AT wichrowskapoloki thermalanalysisoftheatlasdumpsystem |