Cargando…

Evaluation of Radiation Dose Exposure for Silicon Pixel Detectors in ALICE Experiment

An estimation of radiation dose exposure expected for the Inner Tracking System (ITS) of ALICE experiment at the future LHC collider is presented. In particular, the two innermost layers of the silicon ITS, located at radial distances of 3.9 and 7.6cm are based on hybrid silicon pixel detectors. A p...

Descripción completa

Detalles Bibliográficos
Autores principales: Morando, M, Meddi, F
Lenguaje:eng
Publicado: 1996
Materias:
Acceso en línea:https://dx.doi.org/10.1016/S0168-9002(97)00616-5
http://cds.cern.ch/record/689216
_version_ 1780901864735244288
author Morando, M
Meddi, F
author_facet Morando, M
Meddi, F
author_sort Morando, M
collection CERN
description An estimation of radiation dose exposure expected for the Inner Tracking System (ITS) of ALICE experiment at the future LHC collider is presented. In particular, the two innermost layers of the silicon ITS, located at radial distances of 3.9 and 7.6cm are based on hybrid silicon pixel detectors. A possible scenario for the first ten years operation is presented assuming a data taking with beams of lead, calcium and proton.
id cern-689216
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1996
record_format invenio
spelling cern-6892162019-09-30T06:29:59Zdoi:10.1016/S0168-9002(97)00616-5http://cds.cern.ch/record/689216engMorando, MMeddi, FEvaluation of Radiation Dose Exposure for Silicon Pixel Detectors in ALICE ExperimentDetectors and Experimental TechniquesAn estimation of radiation dose exposure expected for the Inner Tracking System (ITS) of ALICE experiment at the future LHC collider is presented. In particular, the two innermost layers of the silicon ITS, located at radial distances of 3.9 and 7.6cm are based on hybrid silicon pixel detectors. A possible scenario for the first ten years operation is presented assuming a data taking with beams of lead, calcium and proton.ALICE-INT-1996-11CERN-ALICE-INT-1996-11oai:cds.cern.ch:6892161996
spellingShingle Detectors and Experimental Techniques
Morando, M
Meddi, F
Evaluation of Radiation Dose Exposure for Silicon Pixel Detectors in ALICE Experiment
title Evaluation of Radiation Dose Exposure for Silicon Pixel Detectors in ALICE Experiment
title_full Evaluation of Radiation Dose Exposure for Silicon Pixel Detectors in ALICE Experiment
title_fullStr Evaluation of Radiation Dose Exposure for Silicon Pixel Detectors in ALICE Experiment
title_full_unstemmed Evaluation of Radiation Dose Exposure for Silicon Pixel Detectors in ALICE Experiment
title_short Evaluation of Radiation Dose Exposure for Silicon Pixel Detectors in ALICE Experiment
title_sort evaluation of radiation dose exposure for silicon pixel detectors in alice experiment
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/S0168-9002(97)00616-5
http://cds.cern.ch/record/689216
work_keys_str_mv AT morandom evaluationofradiationdoseexposureforsiliconpixeldetectorsinaliceexperiment
AT meddif evaluationofradiationdoseexposureforsiliconpixeldetectorsinaliceexperiment