Cargando…
Status of the Gas System for a Pestov Counter Array
The gas system to supply the Pestov counter array by a special gas composition at the pressure of 12 bar is presented. The stability of PesTOF gas mixture composition has been investigated by gaschromatographical methods. The performance of the gas system was dramatically improved by the introductio...
Autores principales: | , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1997
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/689335 |
_version_ | 1780901879565254656 |
---|---|
author | Bosteels, Michel Eschke, J Frankenfeld, Ulrich Lühning, J Lynen, U Pestov, Y N Sann, H Schmidt, H R Schreiber, B M Stelzer, H |
author_facet | Bosteels, Michel Eschke, J Frankenfeld, Ulrich Lühning, J Lynen, U Pestov, Y N Sann, H Schmidt, H R Schreiber, B M Stelzer, H |
author_sort | Bosteels, Michel |
collection | CERN |
description | The gas system to supply the Pestov counter array by a special gas composition at the pressure of 12 bar is presented. The stability of PesTOF gas mixture composition has been investigated by gaschromatographical methods. The performance of the gas system was dramatically improved by the introduction of a standard 50 l gas bottle instead of the rubber compensator which led to a decrease of the organic counter gas components by adsorption. The system now allows a running over several weeks with a stable gas composition. In addition, the influence of the counter spark operation could be identified by the appearances of several new substances in the ppm range. |
id | cern-689335 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1997 |
record_format | invenio |
spelling | cern-6893352019-09-30T06:29:59Zhttp://cds.cern.ch/record/689335engBosteels, MichelEschke, JFrankenfeld, UlrichLühning, JLynen, UPestov, Y NSann, HSchmidt, H RSchreiber, B MStelzer, HStatus of the Gas System for a Pestov Counter ArrayDetectors and Experimental TechniquesThe gas system to supply the Pestov counter array by a special gas composition at the pressure of 12 bar is presented. The stability of PesTOF gas mixture composition has been investigated by gaschromatographical methods. The performance of the gas system was dramatically improved by the introduction of a standard 50 l gas bottle instead of the rubber compensator which led to a decrease of the organic counter gas components by adsorption. The system now allows a running over several weeks with a stable gas composition. In addition, the influence of the counter spark operation could be identified by the appearances of several new substances in the ppm range.ALICE-INT-1997-37CERN-ALICE-INT-1997-37oai:cds.cern.ch:6893351997 |
spellingShingle | Detectors and Experimental Techniques Bosteels, Michel Eschke, J Frankenfeld, Ulrich Lühning, J Lynen, U Pestov, Y N Sann, H Schmidt, H R Schreiber, B M Stelzer, H Status of the Gas System for a Pestov Counter Array |
title | Status of the Gas System for a Pestov Counter Array |
title_full | Status of the Gas System for a Pestov Counter Array |
title_fullStr | Status of the Gas System for a Pestov Counter Array |
title_full_unstemmed | Status of the Gas System for a Pestov Counter Array |
title_short | Status of the Gas System for a Pestov Counter Array |
title_sort | status of the gas system for a pestov counter array |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/689335 |
work_keys_str_mv | AT bosteelsmichel statusofthegassystemforapestovcounterarray AT eschkej statusofthegassystemforapestovcounterarray AT frankenfeldulrich statusofthegassystemforapestovcounterarray AT luhningj statusofthegassystemforapestovcounterarray AT lynenu statusofthegassystemforapestovcounterarray AT pestovyn statusofthegassystemforapestovcounterarray AT sannh statusofthegassystemforapestovcounterarray AT schmidthr statusofthegassystemforapestovcounterarray AT schreiberbm statusofthegassystemforapestovcounterarray AT stelzerh statusofthegassystemforapestovcounterarray |