Cargando…
Pad Segmentation for Stations 4 and 5 of the ALICE Muon Spectrometer
A pad segmentation based on 3 types of PCBs for each cathode plane for the stations 4/5 is presented. PCBs of 40 x 40 cm<SUP>2</SUP> are used with only one pad size on each. The 4 chambers are built with the same mechanics and the electronics are only implemented inside the acceptance. T...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1995
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/689400 |
_version_ | 1780901882470858752 |
---|---|
author | Borel, H Chevrot, I Gosset, J Staley, F Terrien, Y Ageron, P De Girolamo, P Gosset, L Hardy, P Lugol, J C Cussonneau, J P Lautridou, P Luquin, Lionel Dialinas, M Baldisseri, A |
author_facet | Borel, H Chevrot, I Gosset, J Staley, F Terrien, Y Ageron, P De Girolamo, P Gosset, L Hardy, P Lugol, J C Cussonneau, J P Lautridou, P Luquin, Lionel Dialinas, M Baldisseri, A |
author_sort | Borel, H |
collection | CERN |
description | A pad segmentation based on 3 types of PCBs for each cathode plane for the stations 4/5 is presented. PCBs of 40 x 40 cm<SUP>2</SUP> are used with only one pad size on each. The 4 chambers are built with the same mechanics and the electronics are only implemented inside the acceptance. This solution leads to an easier design and construction. The total number of channels for the stations 4 and 5 are found to be 487 680. |
id | cern-689400 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1995 |
record_format | invenio |
spelling | cern-6894002019-09-30T06:29:59Zhttp://cds.cern.ch/record/689400engBorel, HChevrot, IGosset, JStaley, FTerrien, YAgeron, PDe Girolamo, PGosset, LHardy, PLugol, J CCussonneau, J PLautridou, PLuquin, LionelDialinas, MBaldisseri, APad Segmentation for Stations 4 and 5 of the ALICE Muon SpectrometerDetectors and Experimental TechniquesA pad segmentation based on 3 types of PCBs for each cathode plane for the stations 4/5 is presented. PCBs of 40 x 40 cm<SUP>2</SUP> are used with only one pad size on each. The 4 chambers are built with the same mechanics and the electronics are only implemented inside the acceptance. This solution leads to an easier design and construction. The total number of channels for the stations 4 and 5 are found to be 487 680.ALICE-INT-1999-37CERN-ALICE-INT-1999-37oai:cds.cern.ch:6894001995 |
spellingShingle | Detectors and Experimental Techniques Borel, H Chevrot, I Gosset, J Staley, F Terrien, Y Ageron, P De Girolamo, P Gosset, L Hardy, P Lugol, J C Cussonneau, J P Lautridou, P Luquin, Lionel Dialinas, M Baldisseri, A Pad Segmentation for Stations 4 and 5 of the ALICE Muon Spectrometer |
title | Pad Segmentation for Stations 4 and 5 of the ALICE Muon Spectrometer |
title_full | Pad Segmentation for Stations 4 and 5 of the ALICE Muon Spectrometer |
title_fullStr | Pad Segmentation for Stations 4 and 5 of the ALICE Muon Spectrometer |
title_full_unstemmed | Pad Segmentation for Stations 4 and 5 of the ALICE Muon Spectrometer |
title_short | Pad Segmentation for Stations 4 and 5 of the ALICE Muon Spectrometer |
title_sort | pad segmentation for stations 4 and 5 of the alice muon spectrometer |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/689400 |
work_keys_str_mv | AT borelh padsegmentationforstations4and5ofthealicemuonspectrometer AT chevroti padsegmentationforstations4and5ofthealicemuonspectrometer AT gossetj padsegmentationforstations4and5ofthealicemuonspectrometer AT staleyf padsegmentationforstations4and5ofthealicemuonspectrometer AT terrieny padsegmentationforstations4and5ofthealicemuonspectrometer AT ageronp padsegmentationforstations4and5ofthealicemuonspectrometer AT degirolamop padsegmentationforstations4and5ofthealicemuonspectrometer AT gossetl padsegmentationforstations4and5ofthealicemuonspectrometer AT hardyp padsegmentationforstations4and5ofthealicemuonspectrometer AT lugoljc padsegmentationforstations4and5ofthealicemuonspectrometer AT cussonneaujp padsegmentationforstations4and5ofthealicemuonspectrometer AT lautridoup padsegmentationforstations4and5ofthealicemuonspectrometer AT luquinlionel padsegmentationforstations4and5ofthealicemuonspectrometer AT dialinasm padsegmentationforstations4and5ofthealicemuonspectrometer AT baldisseria padsegmentationforstations4and5ofthealicemuonspectrometer |