Cargando…

Pad Segmentation for Stations 4 and 5 of the ALICE Muon Spectrometer

A pad segmentation based on 3 types of PCBs for each cathode plane for the stations 4/5 is presented. PCBs of 40 x 40 cm<SUP>2</SUP> are used with only one pad size on each. The 4 chambers are built with the same mechanics and the electronics are only implemented inside the acceptance. T...

Descripción completa

Detalles Bibliográficos
Autores principales: Borel, H, Chevrot, I, Gosset, J, Staley, F, Terrien, Y, Ageron, P, De Girolamo, P, Gosset, L, Hardy, P, Lugol, J C, Cussonneau, J P, Lautridou, P, Luquin, Lionel, Dialinas, M, Baldisseri, A
Lenguaje:eng
Publicado: 1995
Materias:
Acceso en línea:http://cds.cern.ch/record/689400
_version_ 1780901882470858752
author Borel, H
Chevrot, I
Gosset, J
Staley, F
Terrien, Y
Ageron, P
De Girolamo, P
Gosset, L
Hardy, P
Lugol, J C
Cussonneau, J P
Lautridou, P
Luquin, Lionel
Dialinas, M
Baldisseri, A
author_facet Borel, H
Chevrot, I
Gosset, J
Staley, F
Terrien, Y
Ageron, P
De Girolamo, P
Gosset, L
Hardy, P
Lugol, J C
Cussonneau, J P
Lautridou, P
Luquin, Lionel
Dialinas, M
Baldisseri, A
author_sort Borel, H
collection CERN
description A pad segmentation based on 3 types of PCBs for each cathode plane for the stations 4/5 is presented. PCBs of 40 x 40 cm<SUP>2</SUP> are used with only one pad size on each. The 4 chambers are built with the same mechanics and the electronics are only implemented inside the acceptance. This solution leads to an easier design and construction. The total number of channels for the stations 4 and 5 are found to be 487 680.
id cern-689400
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1995
record_format invenio
spelling cern-6894002019-09-30T06:29:59Zhttp://cds.cern.ch/record/689400engBorel, HChevrot, IGosset, JStaley, FTerrien, YAgeron, PDe Girolamo, PGosset, LHardy, PLugol, J CCussonneau, J PLautridou, PLuquin, LionelDialinas, MBaldisseri, APad Segmentation for Stations 4 and 5 of the ALICE Muon SpectrometerDetectors and Experimental TechniquesA pad segmentation based on 3 types of PCBs for each cathode plane for the stations 4/5 is presented. PCBs of 40 x 40 cm<SUP>2</SUP> are used with only one pad size on each. The 4 chambers are built with the same mechanics and the electronics are only implemented inside the acceptance. This solution leads to an easier design and construction. The total number of channels for the stations 4 and 5 are found to be 487 680.ALICE-INT-1999-37CERN-ALICE-INT-1999-37oai:cds.cern.ch:6894001995
spellingShingle Detectors and Experimental Techniques
Borel, H
Chevrot, I
Gosset, J
Staley, F
Terrien, Y
Ageron, P
De Girolamo, P
Gosset, L
Hardy, P
Lugol, J C
Cussonneau, J P
Lautridou, P
Luquin, Lionel
Dialinas, M
Baldisseri, A
Pad Segmentation for Stations 4 and 5 of the ALICE Muon Spectrometer
title Pad Segmentation for Stations 4 and 5 of the ALICE Muon Spectrometer
title_full Pad Segmentation for Stations 4 and 5 of the ALICE Muon Spectrometer
title_fullStr Pad Segmentation for Stations 4 and 5 of the ALICE Muon Spectrometer
title_full_unstemmed Pad Segmentation for Stations 4 and 5 of the ALICE Muon Spectrometer
title_short Pad Segmentation for Stations 4 and 5 of the ALICE Muon Spectrometer
title_sort pad segmentation for stations 4 and 5 of the alice muon spectrometer
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/689400
work_keys_str_mv AT borelh padsegmentationforstations4and5ofthealicemuonspectrometer
AT chevroti padsegmentationforstations4and5ofthealicemuonspectrometer
AT gossetj padsegmentationforstations4and5ofthealicemuonspectrometer
AT staleyf padsegmentationforstations4and5ofthealicemuonspectrometer
AT terrieny padsegmentationforstations4and5ofthealicemuonspectrometer
AT ageronp padsegmentationforstations4and5ofthealicemuonspectrometer
AT degirolamop padsegmentationforstations4and5ofthealicemuonspectrometer
AT gossetl padsegmentationforstations4and5ofthealicemuonspectrometer
AT hardyp padsegmentationforstations4and5ofthealicemuonspectrometer
AT lugoljc padsegmentationforstations4and5ofthealicemuonspectrometer
AT cussonneaujp padsegmentationforstations4and5ofthealicemuonspectrometer
AT lautridoup padsegmentationforstations4and5ofthealicemuonspectrometer
AT luquinlionel padsegmentationforstations4and5ofthealicemuonspectrometer
AT dialinasm padsegmentationforstations4and5ofthealicemuonspectrometer
AT baldisseria padsegmentationforstations4and5ofthealicemuonspectrometer