Test results of the RASNIK optical alignment monitoring system for the LHCb outer tracker detector
We present the results from tests of the RASNIK optical alignment monitoring system installed on a 5.6 m long optical bench with movable platforms. The measurements of the stability, resolution and linearity of the system show that it performs according to specifications. The effects of temperature...
Autores principales: | , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2001
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/691498 |
Sumario: | We present the results from tests of the RASNIK optical alignment monitoring system installed on a 5.6 m long optical bench with movable platforms. The measurements of the stability, resolution and linearity of the system show that it performs according to specifications. The effects of temperature gradients were also investigated. All the results show that the system is well adapted to the LHCb Outer Tracker needs. |
---|