Cargando…

Material choice for the vacuum container around the LHCb VELO detector

In an effort to minimize the amount of material, we have investigated the use of aluminium and beryllium for the detector vacuum container. Our conclusion is that the increase in cost and R&D for a design with beryllium is disproportionate with the improvement obtained.

Detalles Bibliográficos
Autores principales: Van den Brand, J F J, Doets, M, Ferro-Luzzi, M, Kraan, M G, Mul, F, De Vries, H
Lenguaje:eng
Publicado: 2003
Materias:
Acceso en línea:http://cds.cern.ch/record/691554
_version_ 1780902015190171648
author Van den Brand, J F J
Doets, M
Ferro-Luzzi, M
Kraan, M G
Mul, F
De Vries, H
author_facet Van den Brand, J F J
Doets, M
Ferro-Luzzi, M
Kraan, M G
Mul, F
De Vries, H
author_sort Van den Brand, J F J
collection CERN
description In an effort to minimize the amount of material, we have investigated the use of aluminium and beryllium for the detector vacuum container. Our conclusion is that the increase in cost and R&D for a design with beryllium is disproportionate with the improvement obtained.
id cern-691554
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2003
record_format invenio
spelling cern-6915542019-09-30T06:29:59Zhttp://cds.cern.ch/record/691554engVan den Brand, J F JDoets, MFerro-Luzzi, MKraan, M GMul, FDe Vries, HMaterial choice for the vacuum container around the LHCb VELO detectorDetectors and Experimental TechniquesIn an effort to minimize the amount of material, we have investigated the use of aluminium and beryllium for the detector vacuum container. Our conclusion is that the increase in cost and R&D for a design with beryllium is disproportionate with the improvement obtained.LHCb-2003-055oai:cds.cern.ch:6915542003-08-29
spellingShingle Detectors and Experimental Techniques
Van den Brand, J F J
Doets, M
Ferro-Luzzi, M
Kraan, M G
Mul, F
De Vries, H
Material choice for the vacuum container around the LHCb VELO detector
title Material choice for the vacuum container around the LHCb VELO detector
title_full Material choice for the vacuum container around the LHCb VELO detector
title_fullStr Material choice for the vacuum container around the LHCb VELO detector
title_full_unstemmed Material choice for the vacuum container around the LHCb VELO detector
title_short Material choice for the vacuum container around the LHCb VELO detector
title_sort material choice for the vacuum container around the lhcb velo detector
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/691554
work_keys_str_mv AT vandenbrandjfj materialchoiceforthevacuumcontaineraroundthelhcbvelodetector
AT doetsm materialchoiceforthevacuumcontaineraroundthelhcbvelodetector
AT ferroluzzim materialchoiceforthevacuumcontaineraroundthelhcbvelodetector
AT kraanmg materialchoiceforthevacuumcontaineraroundthelhcbvelodetector
AT mulf materialchoiceforthevacuumcontaineraroundthelhcbvelodetector
AT devriesh materialchoiceforthevacuumcontaineraroundthelhcbvelodetector