Cargando…
An update of the 2x2 implementation for the level 0 calorimeter triggers
1. Introduction The 2x2 implementation for the Level 0 calorimetric triggers is described in Refs. [1, 2]. The purpose of this note is to present a detailed description of the data-flow and hardware implementation in answer to the questions of the Trigger Coordinator Hans Dijkstra. System issues are...
Autores principales: | , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1999
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/691572 |
_version_ | 1780902017762328576 |
---|---|
author | Beigbeder-Beau, C Breton, D Callot, O Cros, P Jean-Marie, B Lefrançois, J Videau, I |
author_facet | Beigbeder-Beau, C Breton, D Callot, O Cros, P Jean-Marie, B Lefrançois, J Videau, I |
author_sort | Beigbeder-Beau, C |
collection | CERN |
description | 1. Introduction The 2x2 implementation for the Level 0 calorimetric triggers is described in Refs. [1, 2]. The purpose of this note is to present a detailed description of the data-flow and hardware implementation in answer to the questions of the Trigger Coordinator Hans Dijkstra. System issues are also addressed, such as the synchronisation of signals from the various detectors, the treatment of a ''loss of clock'' condition and aspects relating to the monitoring and debugging of the functioning of the trigger. We also provide details of cost estimates and the total latency of the trigger. Finally the principal milestones for reaching a final design are given in order to meet the deadline for the Technical Design Report (TDR) by the end of 2001. 2. Front-end Electronics and Detector Geometry In this section we present the current status of the front-end electronics for the subdetectors involved in the calorimetric triggers, as well as their geometry, i.e. dimension and pad size. These parameters are only relevant to the trigger implementation because they play a role in the data-flow and hardware implementation. |
id | cern-691572 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1999 |
record_format | invenio |
spelling | cern-6915722019-09-30T06:29:59Zhttp://cds.cern.ch/record/691572engBeigbeder-Beau, CBreton, DCallot, OCros, PJean-Marie, BLefrançois, JVideau, IAn update of the 2x2 implementation for the level 0 calorimeter triggersDetectors and Experimental Techniques1. Introduction The 2x2 implementation for the Level 0 calorimetric triggers is described in Refs. [1, 2]. The purpose of this note is to present a detailed description of the data-flow and hardware implementation in answer to the questions of the Trigger Coordinator Hans Dijkstra. System issues are also addressed, such as the synchronisation of signals from the various detectors, the treatment of a ''loss of clock'' condition and aspects relating to the monitoring and debugging of the functioning of the trigger. We also provide details of cost estimates and the total latency of the trigger. Finally the principal milestones for reaching a final design are given in order to meet the deadline for the Technical Design Report (TDR) by the end of 2001. 2. Front-end Electronics and Detector Geometry In this section we present the current status of the front-end electronics for the subdetectors involved in the calorimetric triggers, as well as their geometry, i.e. dimension and pad size. These parameters are only relevant to the trigger implementation because they play a role in the data-flow and hardware implementation.LHCb-99-007oai:cds.cern.ch:6915721999-04-29 |
spellingShingle | Detectors and Experimental Techniques Beigbeder-Beau, C Breton, D Callot, O Cros, P Jean-Marie, B Lefrançois, J Videau, I An update of the 2x2 implementation for the level 0 calorimeter triggers |
title | An update of the 2x2 implementation for the level 0 calorimeter triggers |
title_full | An update of the 2x2 implementation for the level 0 calorimeter triggers |
title_fullStr | An update of the 2x2 implementation for the level 0 calorimeter triggers |
title_full_unstemmed | An update of the 2x2 implementation for the level 0 calorimeter triggers |
title_short | An update of the 2x2 implementation for the level 0 calorimeter triggers |
title_sort | update of the 2x2 implementation for the level 0 calorimeter triggers |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/691572 |
work_keys_str_mv | AT beigbederbeauc anupdateofthe2x2implementationforthelevel0calorimetertriggers AT bretond anupdateofthe2x2implementationforthelevel0calorimetertriggers AT calloto anupdateofthe2x2implementationforthelevel0calorimetertriggers AT crosp anupdateofthe2x2implementationforthelevel0calorimetertriggers AT jeanmarieb anupdateofthe2x2implementationforthelevel0calorimetertriggers AT lefrancoisj anupdateofthe2x2implementationforthelevel0calorimetertriggers AT videaui anupdateofthe2x2implementationforthelevel0calorimetertriggers AT beigbederbeauc updateofthe2x2implementationforthelevel0calorimetertriggers AT bretond updateofthe2x2implementationforthelevel0calorimetertriggers AT calloto updateofthe2x2implementationforthelevel0calorimetertriggers AT crosp updateofthe2x2implementationforthelevel0calorimetertriggers AT jeanmarieb updateofthe2x2implementationforthelevel0calorimetertriggers AT lefrancoisj updateofthe2x2implementationforthelevel0calorimetertriggers AT videaui updateofthe2x2implementationforthelevel0calorimetertriggers |