Cargando…

LHCb outer tracker prototypes

This note describes measurements performed on various prototype modules of LHCb Outer Tracker drift chambers in the test beam periods of 1998 and 1999. Presented are measurements of various drift cell characteristics. The single cell efficiency is shown to be better than 98%. The gas mixture Ar:CF4:...

Descripción completa

Detalles Bibliográficos
Autor principal: Van der Eijk, R
Lenguaje:eng
Publicado: 2000
Materias:
Acceso en línea:http://cds.cern.ch/record/691628
_version_ 1780902029092192256
author Van der Eijk, R
author_facet Van der Eijk, R
author_sort Van der Eijk, R
collection CERN
description This note describes measurements performed on various prototype modules of LHCb Outer Tracker drift chambers in the test beam periods of 1998 and 1999. Presented are measurements of various drift cell characteristics. The single cell efficiency is shown to be better than 98%. The gas mixture Ar:CF4:CO2 (68:27:05) in a 5 mm straw tube is just fast enough to keep the maximum drift time within two LHC bunch crossings. It is shown that 8 mm cells do not satisfy this criterium. The noise in the tested 5 mm prototypes is below 0.2%, the main source of this noise is the amplifier/shaper. Next to presenting the measurements, the test beam setup is described. Furthermore a description is given of the used analysis methods. The same methods will be used to analyse the data taken in 2000. This data will be reported in a seperate note.
id cern-691628
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2000
record_format invenio
spelling cern-6916282019-09-30T06:29:59Zhttp://cds.cern.ch/record/691628engVan der Eijk, RLHCb outer tracker prototypesDetectors and Experimental TechniquesThis note describes measurements performed on various prototype modules of LHCb Outer Tracker drift chambers in the test beam periods of 1998 and 1999. Presented are measurements of various drift cell characteristics. The single cell efficiency is shown to be better than 98%. The gas mixture Ar:CF4:CO2 (68:27:05) in a 5 mm straw tube is just fast enough to keep the maximum drift time within two LHC bunch crossings. It is shown that 8 mm cells do not satisfy this criterium. The noise in the tested 5 mm prototypes is below 0.2%, the main source of this noise is the amplifier/shaper. Next to presenting the measurements, the test beam setup is described. Furthermore a description is given of the used analysis methods. The same methods will be used to analyse the data taken in 2000. This data will be reported in a seperate note.LHCb-2000-057oai:cds.cern.ch:6916282000-07-04
spellingShingle Detectors and Experimental Techniques
Van der Eijk, R
LHCb outer tracker prototypes
title LHCb outer tracker prototypes
title_full LHCb outer tracker prototypes
title_fullStr LHCb outer tracker prototypes
title_full_unstemmed LHCb outer tracker prototypes
title_short LHCb outer tracker prototypes
title_sort lhcb outer tracker prototypes
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/691628
work_keys_str_mv AT vandereijkr lhcboutertrackerprototypes