The front-end electronics for LHCb calorimeters
The electronics for the electromagnetic and hadronic calorimeters of LHCb is under design. The 32 channel-9U front-end board offers the complete front-end and readout electronics for every channel including original shaping, 12bit-40MHz ADC, digital filtering and latency for level 0 and level 1 trig...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/691705 |
_version_ | 1780902045439492096 |
---|---|
author | Beigbeder-Beau, C Bernier, R Breton, D Cacéres, T Callot, O Cros, P Delcourt, B De Vivie de Régie, J B Falleau, I Hrisoho, A Jeanmarie, B Lefrançois, J Tocut, V Truong, K D Videau, I |
author_facet | Beigbeder-Beau, C Bernier, R Breton, D Cacéres, T Callot, O Cros, P Delcourt, B De Vivie de Régie, J B Falleau, I Hrisoho, A Jeanmarie, B Lefrançois, J Tocut, V Truong, K D Videau, I |
author_sort | Beigbeder-Beau, C |
collection | CERN |
description | The electronics for the electromagnetic and hadronic calorimeters of LHCb is under design. The 32 channel-9U front-end board offers the complete front-end and readout electronics for every channel including original shaping, 12bit-40MHz ADC, digital filtering and latency for level 0 and level 1 triggers. The clipped PM input signal is integrated during 25ns, but also delayed then subtracted to itself 25ns later which allows performant pile up independence. This board also includes the first processing levels of the L0 calorimeter trigger. A 16 channel-6U prototype board has been designed and used at CERN in test beam in 1999. |
id | cern-691705 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2000 |
record_format | invenio |
spelling | cern-6917052019-09-30T06:29:59Zhttp://cds.cern.ch/record/691705engBeigbeder-Beau, CBernier, RBreton, DCacéres, TCallot, OCros, PDelcourt, BDe Vivie de Régie, J BFalleau, IHrisoho, AJeanmarie, BLefrançois, JTocut, VTruong, K DVideau, IThe front-end electronics for LHCb calorimetersDetectors and Experimental TechniquesThe electronics for the electromagnetic and hadronic calorimeters of LHCb is under design. The 32 channel-9U front-end board offers the complete front-end and readout electronics for every channel including original shaping, 12bit-40MHz ADC, digital filtering and latency for level 0 and level 1 triggers. The clipped PM input signal is integrated during 25ns, but also delayed then subtracted to itself 25ns later which allows performant pile up independence. This board also includes the first processing levels of the L0 calorimeter trigger. A 16 channel-6U prototype board has been designed and used at CERN in test beam in 1999.LHCb-2000-028oai:cds.cern.ch:6917052000-10-27 |
spellingShingle | Detectors and Experimental Techniques Beigbeder-Beau, C Bernier, R Breton, D Cacéres, T Callot, O Cros, P Delcourt, B De Vivie de Régie, J B Falleau, I Hrisoho, A Jeanmarie, B Lefrançois, J Tocut, V Truong, K D Videau, I The front-end electronics for LHCb calorimeters |
title | The front-end electronics for LHCb calorimeters |
title_full | The front-end electronics for LHCb calorimeters |
title_fullStr | The front-end electronics for LHCb calorimeters |
title_full_unstemmed | The front-end electronics for LHCb calorimeters |
title_short | The front-end electronics for LHCb calorimeters |
title_sort | front-end electronics for lhcb calorimeters |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/691705 |
work_keys_str_mv | AT beigbederbeauc thefrontendelectronicsforlhcbcalorimeters AT bernierr thefrontendelectronicsforlhcbcalorimeters AT bretond thefrontendelectronicsforlhcbcalorimeters AT cacerest thefrontendelectronicsforlhcbcalorimeters AT calloto thefrontendelectronicsforlhcbcalorimeters AT crosp thefrontendelectronicsforlhcbcalorimeters AT delcourtb thefrontendelectronicsforlhcbcalorimeters AT deviviederegiejb thefrontendelectronicsforlhcbcalorimeters AT falleaui thefrontendelectronicsforlhcbcalorimeters AT hrisohoa thefrontendelectronicsforlhcbcalorimeters AT jeanmarieb thefrontendelectronicsforlhcbcalorimeters AT lefrancoisj thefrontendelectronicsforlhcbcalorimeters AT tocutv thefrontendelectronicsforlhcbcalorimeters AT truongkd thefrontendelectronicsforlhcbcalorimeters AT videaui thefrontendelectronicsforlhcbcalorimeters AT beigbederbeauc frontendelectronicsforlhcbcalorimeters AT bernierr frontendelectronicsforlhcbcalorimeters AT bretond frontendelectronicsforlhcbcalorimeters AT cacerest frontendelectronicsforlhcbcalorimeters AT calloto frontendelectronicsforlhcbcalorimeters AT crosp frontendelectronicsforlhcbcalorimeters AT delcourtb frontendelectronicsforlhcbcalorimeters AT deviviederegiejb frontendelectronicsforlhcbcalorimeters AT falleaui frontendelectronicsforlhcbcalorimeters AT hrisohoa frontendelectronicsforlhcbcalorimeters AT jeanmarieb frontendelectronicsforlhcbcalorimeters AT lefrancoisj frontendelectronicsforlhcbcalorimeters AT tocutv frontendelectronicsforlhcbcalorimeters AT truongkd frontendelectronicsforlhcbcalorimeters AT videaui frontendelectronicsforlhcbcalorimeters |