Power converter failure of the normal conducting D1 magnet at experiment insertions IR1 and IR5

Power converter failures of the warm D1 magnets at the high luminosity experiment insertions IR1 and IR5 can lead to beam losses in the collimation insertion of IR7 within a few turns. The note presents the results obtained with a fast linear particle tracking for a tripping of the power converter o...

Descripción completa

Detalles Bibliográficos
Autor principal: Kain, V
Lenguaje:eng
Publicado: 2003
Materias:
Acceso en línea:http://cds.cern.ch/record/691816
_version_ 1780902068726267904
author Kain, V
author_facet Kain, V
author_sort Kain, V
collection CERN
description Power converter failures of the warm D1 magnets at the high luminosity experiment insertions IR1 and IR5 can lead to beam losses in the collimation insertion of IR7 within a few turns. The note presents the results obtained with a fast linear particle tracking for a tripping of the power converter of the normal conducting D1 magnets. The data was cross-checked with MAD-X including non-linear magnetic fields. Losses were determined at several collimator and absorber locations sitting close to the beam. Apertures at loss locations were treated as black absorbers.
id cern-691816
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2003
record_format invenio
spelling cern-6918162023-05-31T13:25:03Zhttp://cds.cern.ch/record/691816engKain, VPower converter failure of the normal conducting D1 magnet at experiment insertions IR1 and IR5Accelerators and Storage RingsPower converter failures of the warm D1 magnets at the high luminosity experiment insertions IR1 and IR5 can lead to beam losses in the collimation insertion of IR7 within a few turns. The note presents the results obtained with a fast linear particle tracking for a tripping of the power converter of the normal conducting D1 magnets. The data was cross-checked with MAD-X including non-linear magnetic fields. Losses were determined at several collimator and absorber locations sitting close to the beam. Apertures at loss locations were treated as black absorbers.LHC-PROJECT-NOTE-322oai:cds.cern.ch:6918162003-09-16
spellingShingle Accelerators and Storage Rings
Kain, V
Power converter failure of the normal conducting D1 magnet at experiment insertions IR1 and IR5
title Power converter failure of the normal conducting D1 magnet at experiment insertions IR1 and IR5
title_full Power converter failure of the normal conducting D1 magnet at experiment insertions IR1 and IR5
title_fullStr Power converter failure of the normal conducting D1 magnet at experiment insertions IR1 and IR5
title_full_unstemmed Power converter failure of the normal conducting D1 magnet at experiment insertions IR1 and IR5
title_short Power converter failure of the normal conducting D1 magnet at experiment insertions IR1 and IR5
title_sort power converter failure of the normal conducting d1 magnet at experiment insertions ir1 and ir5
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/691816
work_keys_str_mv AT kainv powerconverterfailureofthenormalconductingd1magnetatexperimentinsertionsir1andir5