Measurements of the relative sensitivities between some beam-loss monitors, PART II
We measured the relative sensitivity of various types of classical beam-loss monitors following on from and in the spirit of a previous work. The detectors were tested in one of the SPS extraction l ines. The particles passing through the line consist of 2/3 protons and 1/3 pions at 120 Gev/c. The l...
Autores principales: | , |
---|---|
Lenguaje: | eng |
Publicado: |
1998
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/702451 |
_version_ | 1780902295667474432 |
---|---|
author | Bosser, Jacques Ferioli, G |
author_facet | Bosser, Jacques Ferioli, G |
author_sort | Bosser, Jacques |
collection | CERN |
description | We measured the relative sensitivity of various types of classical beam-loss monitors following on from and in the spirit of a previous work. The detectors were tested in one of the SPS extraction l ines. The particles passing through the line consist of 2/3 protons and 1/3 pions at 120 Gev/c. The low extracted (spill time 2.5 s) beam intensity can be adjusted. Upstream of the detectors a copp er target (diameter: 7 cm, length: 50 cm) can be placed on the beam axis. First we proceed with linearity and sensitivity measurements of various types of detectors used in counting or analog mode. Next, with a view to increasing the dynamic range we pursue out tests with a dedicated type of electronics. Finally, measurements have been made in order to determine, in the frame of our experiment , the minimum detection level of some monitors. |
id | cern-702451 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1998 |
record_format | invenio |
spelling | cern-7024512023-05-11T12:03:24Zhttp://cds.cern.ch/record/702451engBosser, JacquesFerioli, GMeasurements of the relative sensitivities between some beam-loss monitors, PART IIAccelerators and Storage RingsWe measured the relative sensitivity of various types of classical beam-loss monitors following on from and in the spirit of a previous work. The detectors were tested in one of the SPS extraction l ines. The particles passing through the line consist of 2/3 protons and 1/3 pions at 120 Gev/c. The low extracted (spill time 2.5 s) beam intensity can be adjusted. Upstream of the detectors a copp er target (diameter: 7 cm, length: 50 cm) can be placed on the beam axis. First we proceed with linearity and sensitivity measurements of various types of detectors used in counting or analog mode. Next, with a view to increasing the dynamic range we pursue out tests with a dedicated type of electronics. Finally, measurements have been made in order to determine, in the frame of our experiment , the minimum detection level of some monitors.SL-Note-98-027-BIoai:cds.cern.ch:7024511998-02-25 |
spellingShingle | Accelerators and Storage Rings Bosser, Jacques Ferioli, G Measurements of the relative sensitivities between some beam-loss monitors, PART II |
title | Measurements of the relative sensitivities between some beam-loss monitors, PART II |
title_full | Measurements of the relative sensitivities between some beam-loss monitors, PART II |
title_fullStr | Measurements of the relative sensitivities between some beam-loss monitors, PART II |
title_full_unstemmed | Measurements of the relative sensitivities between some beam-loss monitors, PART II |
title_short | Measurements of the relative sensitivities between some beam-loss monitors, PART II |
title_sort | measurements of the relative sensitivities between some beam-loss monitors, part ii |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/702451 |
work_keys_str_mv | AT bosserjacques measurementsoftherelativesensitivitiesbetweensomebeamlossmonitorspartii AT feriolig measurementsoftherelativesensitivitiesbetweensomebeamlossmonitorspartii |