Measurements of the relative sensitivities between some beam-loss monitors, PART II

We measured the relative sensitivity of various types of classical beam-loss monitors following on from and in the spirit of a previous work. The detectors were tested in one of the SPS extraction l ines. The particles passing through the line consist of 2/3 protons and 1/3 pions at 120 Gev/c. The l...

Descripción completa

Detalles Bibliográficos
Autores principales: Bosser, Jacques, Ferioli, G
Lenguaje:eng
Publicado: 1998
Materias:
Acceso en línea:http://cds.cern.ch/record/702451
_version_ 1780902295667474432
author Bosser, Jacques
Ferioli, G
author_facet Bosser, Jacques
Ferioli, G
author_sort Bosser, Jacques
collection CERN
description We measured the relative sensitivity of various types of classical beam-loss monitors following on from and in the spirit of a previous work. The detectors were tested in one of the SPS extraction l ines. The particles passing through the line consist of 2/3 protons and 1/3 pions at 120 Gev/c. The low extracted (spill time 2.5 s) beam intensity can be adjusted. Upstream of the detectors a copp er target (diameter: 7 cm, length: 50 cm) can be placed on the beam axis. First we proceed with linearity and sensitivity measurements of various types of detectors used in counting or analog mode. Next, with a view to increasing the dynamic range we pursue out tests with a dedicated type of electronics. Finally, measurements have been made in order to determine, in the frame of our experiment , the minimum detection level of some monitors.
id cern-702451
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1998
record_format invenio
spelling cern-7024512023-05-11T12:03:24Zhttp://cds.cern.ch/record/702451engBosser, JacquesFerioli, GMeasurements of the relative sensitivities between some beam-loss monitors, PART IIAccelerators and Storage RingsWe measured the relative sensitivity of various types of classical beam-loss monitors following on from and in the spirit of a previous work. The detectors were tested in one of the SPS extraction l ines. The particles passing through the line consist of 2/3 protons and 1/3 pions at 120 Gev/c. The low extracted (spill time 2.5 s) beam intensity can be adjusted. Upstream of the detectors a copp er target (diameter: 7 cm, length: 50 cm) can be placed on the beam axis. First we proceed with linearity and sensitivity measurements of various types of detectors used in counting or analog mode. Next, with a view to increasing the dynamic range we pursue out tests with a dedicated type of electronics. Finally, measurements have been made in order to determine, in the frame of our experiment , the minimum detection level of some monitors.SL-Note-98-027-BIoai:cds.cern.ch:7024511998-02-25
spellingShingle Accelerators and Storage Rings
Bosser, Jacques
Ferioli, G
Measurements of the relative sensitivities between some beam-loss monitors, PART II
title Measurements of the relative sensitivities between some beam-loss monitors, PART II
title_full Measurements of the relative sensitivities between some beam-loss monitors, PART II
title_fullStr Measurements of the relative sensitivities between some beam-loss monitors, PART II
title_full_unstemmed Measurements of the relative sensitivities between some beam-loss monitors, PART II
title_short Measurements of the relative sensitivities between some beam-loss monitors, PART II
title_sort measurements of the relative sensitivities between some beam-loss monitors, part ii
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/702451
work_keys_str_mv AT bosserjacques measurementsoftherelativesensitivitiesbetweensomebeamlossmonitorspartii
AT feriolig measurementsoftherelativesensitivitiesbetweensomebeamlossmonitorspartii