Summary A good matching between the optics parameters at the extraction point in the PS ring and those at the injection point in the SPS ring must be performed in order to minimize the emittance bl ow-up of the beams at injection. The TT2/TT10 transfer line optics was modelled and matched using the...

Descripción completa

Detalles Bibliográficos
Autores principales: Arduini, Gianluigi, Giovannozzi, Massimo, Hanke, K, Hémery, J Y
Lenguaje:eng
Publicado: 1998
Materias:
Acceso en línea:http://cds.cern.ch/record/702479
_version_ 1780902300682813440
author Arduini, Gianluigi
Giovannozzi, Massimo
Hanke, K
Hémery, J Y
author_facet Arduini, Gianluigi
Giovannozzi, Massimo
Hanke, K
Hémery, J Y
author_sort Arduini, Gianluigi
collection CERN
description Summary A good matching between the optics parameters at the extraction point in the PS ring and those at the injection point in the SPS ring must be performed in order to minimize the emittance bl ow-up of the beams at injection. The TT2/TT10 transfer line optics was modelled and matched using the program package MAD. The model relies on a good knwoledge of the calibration curves for the quadru poles and might be hampered by hardware errors e.g. inter-turn coil shorts. In order to verify the calibration curves and tet the absence of hardware faults, the sine-like component of the transfer ma trix has been meassured deflecting the beam by means of dipole correctors. The results of the measurement were found in good agreement with those obtained from the MAD model.
id cern-702479
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1998
record_format invenio
spelling cern-7024792023-05-11T12:03:25Zhttp://cds.cern.ch/record/702479engArduini, GianluigiGiovannozzi, MassimoHanke, KHémery, J YStudy of the TT2/TT10 Transfer Line Optics via Transfer Matrix MeasurementAccelerators and Storage RingsSummary A good matching between the optics parameters at the extraction point in the PS ring and those at the injection point in the SPS ring must be performed in order to minimize the emittance bl ow-up of the beams at injection. The TT2/TT10 transfer line optics was modelled and matched using the program package MAD. The model relies on a good knwoledge of the calibration curves for the quadru poles and might be hampered by hardware errors e.g. inter-turn coil shorts. In order to verify the calibration curves and tet the absence of hardware faults, the sine-like component of the transfer ma trix has been meassured deflecting the beam by means of dipole correctors. The results of the measurement were found in good agreement with those obtained from the MAD model.SL-Note-98-058-MDoai:cds.cern.ch:7024791998-09-09
spellingShingle Accelerators and Storage Rings
Arduini, Gianluigi
Giovannozzi, Massimo
Hanke, K
Hémery, J Y
Study of the TT2/TT10 Transfer Line Optics via Transfer Matrix Measurement
title Study of the TT2/TT10 Transfer Line Optics via Transfer Matrix Measurement
title_full Study of the TT2/TT10 Transfer Line Optics via Transfer Matrix Measurement
title_fullStr Study of the TT2/TT10 Transfer Line Optics via Transfer Matrix Measurement
title_full_unstemmed Study of the TT2/TT10 Transfer Line Optics via Transfer Matrix Measurement
title_short Study of the TT2/TT10 Transfer Line Optics via Transfer Matrix Measurement
title_sort study of the tt2/tt10 transfer line optics via transfer matrix measurement
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/702479
work_keys_str_mv AT arduinigianluigi studyofthett2tt10transferlineopticsviatransfermatrixmeasurement
AT giovannozzimassimo studyofthett2tt10transferlineopticsviatransfermatrixmeasurement
AT hankek studyofthett2tt10transferlineopticsviatransfermatrixmeasurement
AT hemeryjy studyofthett2tt10transferlineopticsviatransfermatrixmeasurement