Comparison and calibration of LEP bunch length measurements

Measurements have been made on short bunches (2 - 5 mm) at 22 GeV and 45 GeV with all wiggler magnets ramped down or off. The bunch lengths obtained from the streak camera and button monitor have be en compared with theoretical predictions. The variation of the streak camera bunch lengths with Q$_S$...

Descripción completa

Detalles Bibliográficos
Autores principales: Burns, A J, Jonker, M, Savioz, J J, Vos, L, Wenninger, J
Lenguaje:eng
Publicado: 1998
Materias:
Acceso en línea:http://cds.cern.ch/record/702481
_version_ 1780902301120069632
author Burns, A J
Jonker, M
Savioz, J J
Vos, L
Wenninger, J
author_facet Burns, A J
Jonker, M
Savioz, J J
Vos, L
Wenninger, J
author_sort Burns, A J
collection CERN
description Measurements have been made on short bunches (2 - 5 mm) at 22 GeV and 45 GeV with all wiggler magnets ramped down or off. The bunch lengths obtained from the streak camera and button monitor have be en compared with theoretical predictions. The variation of the streak camera bunch lengths with Q$_S$ agrees with the predictions, although the measured difference between the length of 95 $\mu$A and 25 $\mu$A bunches is much less than expected from 1997 button monitor measurements. After an offline correction, the button monitor analysis still indicates substantially less than the expecte d variation of bunch length with Q$_S$. However, after the button monitor algorithm was modified on 28$^th$ July, the two measurements agreed within 0.2 mm in the range of bunch lengths 9 - 11 mm . In addition, the response ratio (button / streak) to bunch length variation observed in the range 9 - 13 mm improved from 0.55 to 0.80.
id cern-702481
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1998
record_format invenio
spelling cern-7024812023-05-11T12:03:25Zhttp://cds.cern.ch/record/702481engBurns, A JJonker, MSavioz, J JVos, LWenninger, JComparison and calibration of LEP bunch length measurementsAccelerators and Storage RingsMeasurements have been made on short bunches (2 - 5 mm) at 22 GeV and 45 GeV with all wiggler magnets ramped down or off. The bunch lengths obtained from the streak camera and button monitor have be en compared with theoretical predictions. The variation of the streak camera bunch lengths with Q$_S$ agrees with the predictions, although the measured difference between the length of 95 $\mu$A and 25 $\mu$A bunches is much less than expected from 1997 button monitor measurements. After an offline correction, the button monitor analysis still indicates substantially less than the expecte d variation of bunch length with Q$_S$. However, after the button monitor algorithm was modified on 28$^th$ July, the two measurements agreed within 0.2 mm in the range of bunch lengths 9 - 11 mm . In addition, the response ratio (button / streak) to bunch length variation observed in the range 9 - 13 mm improved from 0.55 to 0.80.SL-Note-98-060-MDoai:cds.cern.ch:7024811998-09-23
spellingShingle Accelerators and Storage Rings
Burns, A J
Jonker, M
Savioz, J J
Vos, L
Wenninger, J
Comparison and calibration of LEP bunch length measurements
title Comparison and calibration of LEP bunch length measurements
title_full Comparison and calibration of LEP bunch length measurements
title_fullStr Comparison and calibration of LEP bunch length measurements
title_full_unstemmed Comparison and calibration of LEP bunch length measurements
title_short Comparison and calibration of LEP bunch length measurements
title_sort comparison and calibration of lep bunch length measurements
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/702481
work_keys_str_mv AT burnsaj comparisonandcalibrationoflepbunchlengthmeasurements
AT jonkerm comparisonandcalibrationoflepbunchlengthmeasurements
AT saviozjj comparisonandcalibrationoflepbunchlengthmeasurements
AT vosl comparisonandcalibrationoflepbunchlengthmeasurements